AT32UC3A464 Atmel Corporation, AT32UC3A464 Datasheet - Page 940

no-image

AT32UC3A464

Manufacturer Part Number
AT32UC3A464
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3A464

Flash (kbytes)
64 Kbytes
Pin Count
100
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
Hardware Qtouch Acquisition
No
Usb Transceiver
1
Usb Speed
Hi-Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
2
Uart
4
Ssc
1
Sd / Emmc
2
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
128
Self Program Memory
YES
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Timers
6
Output Compare Channels
6
Input Capture Channels
6
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3A464-C1UR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A464-C1UT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3A464-CIUT
Manufacturer:
ATMEL
Quantity:
180
Part Number:
AT32UC3A464-CIUT
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT32UC3A464-U
Manufacturer:
XILINX
Quantity:
1
Part Number:
AT32UC3A464S-U
Manufacturer:
ATMEL
Quantity:
551
34.5.2.4
34.5.2.5
32072G–11/2011
INTEST
CLAMP
This instruction selects the boundary-scan chain as Data Register for testing internal logic in the
device. The logic inputs are determined by the boundary-scan chain, and the logic outputs are
captured by the boundary-scan chain. The device output pins are driven from the boundary-scan
chain.
Starting in Run-Test/Idle, the INTEST instruction is accessed the following way:
Table 34-13. INTEST Details
This instruction selects the Bypass register as Data Register. The device output pins are driven
from the boundary-scan chain.
Starting in Run-Test/Idle, the CLAMP instruction is accessed the following way:
Instructions
IR input value
IR output value
DR Size
DR input value
DR output value
1. Select the IR Scan path.
2. In Capture-IR: The IR output value is latched into the shift register.
3. In Shift-IR: The instruction register is shifted by the TCK input.
4. In Update-IR: The data from the boundary-scan chain is applied to the internal logic
5. Return to Run-Test/Idle.
6. Select the DR Scan path.
7. In Capture-DR: The data on the internal logic is sampled into the boundary-scan chain.
8. In Shift-DR: The boundary-scan chain is shifted by the TCK input.
9. In Update-DR: The data from the boundary-scan chain is applied to internal logic
10. Return to Run-Test/Idle.
1. Select the IR Scan path.
2. In Capture-IR: The IR output value is latched into the shift register.
3. In Shift-IR: The instruction register is shifted by the TCK input.
4. In Update-IR: The data from the boundary-scan chain is applied to the output pins.
5. Return to Run-Test/Idle.
6. Select the DR Scan path.
7. In Capture-DR: A logic ‘0’ is loaded into the Bypass Register.
8. In Shift-DR: Data is scanned from TDI to TDO through the Bypass register.
inputs.
inputs.
Details
00100 (0x04)
p0001
Depending on boundary-scan chain, see BSDL-file.
Depending on boundary-scan chain, see BSDL-file.
Depending on boundary-scan chain, see BSDL-file.
940