Auxiliary Area Allocations
A264 to
A265
A270
A295
A300
A302
A316
A318
A319
A330 to
A335
A336
Word
00 to 15 Present Cycle Time
00
01
02
03
11
12
13
14
15
00 to 15 Error Log Pointer
00 to 15 CPU Bus Unit Initializing Flags
05
06
14
02
03
04
05
08
09
10
11
15
00 to 15 RS-422A Port Reception Counter (no-proto-
00 to 15 Special I/O Unit Initializing Flags
00 to 15 Units Detected at Startup (Racks 0 and 1)
Bits
Motion Control Module slot 1
Motion Control Module slot 2
Motion Control Module slot 3
Motion Control Module slot 4
No END Error Flag
Task Error Flag
Differentiation Overflow Error Flag
Illegal Instruction Error Flag
UM Overflow Error Flag
Constant Cycle Time Exceeded Error Clear
Bit
Sync Cycle Time Too Long Flag
Memory Not Held Flag
RS-422A
Port
Error
Flags
RS-422A Port Communications Error Flag
RS-422A Port Send Ready Flag (no-protocol
mode)
RS-422A Port Reception Completed Flag (no-
protocol mode)
RS-422A Port Reception Overflow Flag (no-
protocol mode)
RS-422A Port Settings Changing Flag
col mode)
Parity Error Flag
Framing Error Flag
Overrun Error Flag
Timeout Error Flag
Name
These words stores the present cycle time every cycle in 8-digit
hexadecimal (unit: 0.01 ms).
ON if the Motion Control Module is in slot 1.
ON if the Motion Control Module is in slot 2.
ON if the Motion Control Module is in slot 3.
ON if the Motion Control Module is in slot 4.
ON when there isn’t an END(001) instruction in each program within
a task.
ON when a task error has occurred. The following conditions gener-
ate a task error.
There isn’t a program allocated to the task.
The allowed value for Differentiation Flags which correspond to dif-
ferentiation instructions has been exceeded.
ON when a program that cannot be executed has been stored.
ON when the last address in UM (User Memory) has been
exceeded.
When an error occurs, the Error Log Pointer (binary) is incremented
by 1 to indicate the location where the next error will be recorded as
an offset from the beginning of the Error Log Area (A100 to A199).
Range: 00 to 14 hex
These flags are ON while the corresponding CPU Bus Unit is initializ-
ing after its CPU Bus Unit Restart Bit (A501.00 to A501.15) is turned
from OFF to ON or the power is turned ON.
Note This area is valid only when an FQM1-CM002 is being used.
Used to enable the constant cycle time function again after the con-
stant cycle time has been exceeded.
Turns ON when one of the Modules exceeds the specified sync cycle
time. (Coordinator Module only)
Turns ON when corruption is found in the check performed after turn-
ing ON power in the areas backed up during power interruptions (DM
Area (Motion Control Module only) and Error Log Area).
These error flags turn ON when an error has occurred at the RS-
422A port.
Turns ON when a communications error has occurred at the RS-
422A port.
Turns ON when the RS-422A port is ready to send data in no-proto-
col mode.
Turns ON when the RS-422A port has completed the reception in no-
protocol mode.
Turns ON when a data overflow occurred during reception through
the RS-422A port in no-protocol mode.
Turns ON while the RS-422A port’s communications settings are
being changed.
Indicates (in binary) the number of bytes of data received when the
RS-422A port is in no-protocol mode.
These flags are ON while the corresponding Special I/O Unit is ini-
tializing after its Special I/O Unit Restart Bit (A502.10 to A507.15) is
turned from OFF to ON or the power is turned ON.
Note Unit numbers 0 to 9 cannot be set on Special I/O Units, so
The number of Units detected on each Rack is stored in 1-digit hexa-
decimal (0 to A hex).
Rack 0: A336.00 to A336.03
Rack 1: A336.04 to A336.07
Note Motion Control Modules are not included in the detected Units.
A330.00 to A330.09 are not used.
Function
Appendix D