Signal Range: 1 to 5 V and 4 to 20 mA
Signal Range: 0 to 5 V
7-9-7
Overview
CTBL(882) Instruction
Operation
Analog Input Functions
High-speed Analog Sampling (FQM1-MMA22 Only)
When an FQM1-MMA22 Motion Control Module is being used, the Motion
Control Module can be synchronized with pulse inputs from the encoder to
collect analog data.
This sampling method checks measurements in synchronization with the
position, an operation which could not be performed with scheduled interrupts
in earlier controllers.
When the CTBL(882) instruction is used as a high-speed analog sampling
function, the Motion Control Module can start sampling analog input data at
high speed when a preset counter PV is reached, and store the specified
number of samples automatically in the DM Area.
This function can be used with high-speed counter 1 only.
The CTBL(882) instruction starts a specified interrupt task when the
high-speed counter PV of pulse input 1 matches a specified target value.
If the CTBL(882) instruction is executed in an interrupt task to perform
high-speed analog sampling, pulses on pulse input 1 will be counted using the
ring counter size specified with INI(880) and the Motion Control Module will
sample analog values at each target value specified with the CTBL(882)
instruction.
Analog input (V)
+5.25 V
+5.00 V
Analog input (V)
+5.2 V
+5.0 V
0.25 V
+1.0 V
+0.8 V
0 V
FF38
FF38
0000
0000
Resolution of 1/4,000
Resolution of 1/4,000
0FA0
Analog input (mA)
0FA0
1068
1068
Stored value
(4-digit Hexadecimal)
+20.8 mA
+20.0 mA
+4.0 mA
+3.2 mA
Stored value
(4-digit Hexadecimal)
Section 7-9