C-5 Auxiliary Area Allocations by Function
The following tables list the words and bits allocated in the Auxiliary Area by function. These tables provide only
an overview of the functionality. Refer to Appendix D Auxiliary Area Allocations for details or a list of allocations
by address.
Motion Control Modules
Allocations that are the Same for All Modules
Error-related Settings (Same for All Modules)
Module Errors
Memory Errors
408
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
A270
A751
A752
A402
A403
Address
Address
Address
00
01
02
03
11
12
13
14
15
00 to 15 DM Save Password
08
14
13
Bits
Bits
Bits
Motion Control Module
slot 1
Motion Control Module
slot 2
Motion Control Module
slot 3
Motion Control Module
slot 4
Saved DM Data Invalid
Flag
Invalid DM Save Pass-
word Flag
DM Backup Error Flag
Saving DM Flag
DM Save Start Bit
Coordinator Module
WDT Error Flag (Motion
Control Modules only)
Coordinator Module
Fatal Error Flag (Motion
Control Modules only)
Analog Offset/Gain
Error Flag
Name
Name
Name
ON if the Motion Control Module is in slot 1.
ON if the Motion Control Module is in slot 2.
ON if the Motion Control Module is in slot 3.
ON if the Motion Control Module is in slot 4.
ON if the DM data in flash memory was invalid when it was read. This
flag is cleared when DM data is saved.
ON if A752 contains the wrong password.
ON if the DM data save operation failed.
ON when DM data is being saved to flash memory.
Write the password to A752 and turn this bit ON to save DM data to
flash memory. The data can be saved only when the Motion Control
Module is in PROGRAM mode.
Write A5A5 hex to this word and turn ON the DM Save Start Bit
(A751.15) to transfer DM data to flash memory (PROGRAM mode
only). When the DM data transfer is completed, this word is automati-
cally cleared.
Turns ON in the Motion Control Modules when a WDT error occurs in
the Coordinator Module.
Turns ON in the Motion Control Modules when a fatal error occurs in
the Coordinator Module.
Turns ON when there is an error in the analog I/O offset/gain adjust-
ment value in flash memory.
Note This flag is valid for the FQM1-MMA22 only.
Function
Function
Function
Appendix C
Module
Module
User
Module
Module
Controlled by
Controlled by
Controlled by