FQM1-TER01 Omron, FQM1-TER01 Datasheet - Page 226

no-image

FQM1-TER01

Manufacturer Part Number
FQM1-TER01
Description
5M 4COND 22AWG TPE ST MALE M12
Manufacturer
Omron
Datasheet

Specifications of FQM1-TER01

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
FQM1TER01
7-3-5
Input Interrupt Mode Procedure
Counter Mode Procedure
Input Interrupts
Using Input Interrupts
Interrupt
input
0
1
2
3
1,2,3...
1,2,3...
CIO 2960.00
CIO 2960.01
CIO 2960.02
CIO 2960.03
1. Determine which input interrupt number will be used.
2. Wire the input.
3. Make the necessary System Setup settings.
4. Create the necessary ladder programming.
1. Determine which input interrupt number will be used.
2. Determine the initial SV for the decrementing counter.
Counter operation
Input method
Counting speed
Counter value
Counter PV storage
Counter SV storage
• Set the Interrupt Input Settings (set whether an interrupt will be generated
• Use the MSKS(690) instruction (SET INTERRUPT MASK) to enable the
• Create the interrupt task program.
when the input turns ON, OFF, or both).
Note The default input setting is for a normal input.
input as an interrupt input.
External interrupt input 0
External interrupt input 1
External interrupt input 2
External interrupt input 3
Interrupt input 0
Interrupt input 1
Interrupt input 2
Interrupt input 3
Interrupt input
settings
System Setup
Item
Input
Decrementing pulse input
Single phase
2 kHz
0000 to FFFF hex
Input interrupts 0 to 3 (CIO 2960.00 to CIO 2960.03):
A536 to A539
Input interrupts 0 to 3 (CIO 2960.00 to CIO 2960.03):
A532 to A535
MSKS
Ladder program
Interrupt control
Enable interrupt inputs
CIO 2960.00
CIO 2960.01
CIO 2960.02
CIO 2960.03
Allocated input bit
Specification
Interrupt generated.
Execute specified task.
END
000
001
002
003
Interrupt task number
Section 7-3
199