PEB3081FV14XP Lantiq, PEB3081FV14XP Datasheet - Page 164

PEB3081FV14XP

Manufacturer Part Number
PEB3081FV14XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3081FV14XP

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
Preliminary
4.3.18
Value after reset: 00
MOSR
MDR ... MONITOR channel Data Received
MER ... MONITOR channel End of Reception
MDA ... MONITOR channel Data Acknowledged
The remote end has acknowledged the MONITOR byte being transmitted.
MAB ... MONITOR channel Data Abort
4.3.19
Value after reset: 00
MOCR
MRE ... MONITOR Receive Interrupt Enable
0: MONITOR interrupt status MDR generation is masked
1: MONITOR interrupt status MDR generation is enabled
MRC ... MR Bit Control
Determines the value of the MR bit:
0: MR is always ’1’. In addition, the MDR interrupt is blocked, except for the first byte of
1: MR is internally controlled by the SBCX-X according to MONITOR channel protocol.
Data Sheet
a packet (if MRE = 1).
In addition, the MDR interrupt is enabled for all received bytes according to the
MONITOR channel protocol (if MRE = 1).
7
7
MOSR - MONITOR Interrupt Status Register
MOCR - MONITOR Control Register
MDR
MRE
MER
MRC
H
H
MDA
MIE
MXC
MAB
164
0
0
0
0
Detailed Register Description
0
0
0
0
0
0
RD/WR (5E)
PEB 3081
PEF 3081
2000-09-27
RD (5D)