PEB3081FV14XP Lantiq, PEB3081FV14XP Datasheet - Page 111

PEB3081FV14XP

Manufacturer Part Number
PEB3081FV14XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3081FV14XP

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
Preliminary
3.7.5.1
The TIC bus is imlemented to organize the access to the layer-1 functions provided in
the SBCX-X (C/I-channel) and to the D-channel from up to 7 external communication
controllers
To this effect the outputs of the D-channel controllers (e.g. ICC - ISDN Communication
Controller PEB 2070) are wired-or (negative logic, i.e. a “0” wins) and connected to pin
DU. The inputs of the ICCs are connected to pin DD. External pull-up resistors on DU/
DD are required. The arbitration mechanism must be activated by setting
TR_MODE2.DIM2-0=00x.
Figure 59
The arbitration mechanism is implemented in the last octet in IOM-2 channel 2 of the
IOM-2 interface
by software via a µP access to the C/I channel or by one of the D-channel controllers
(ICC). A software access request to the bus is effected by setting the BAC bit (CIX0
register) to ’1’.
Data Sheet
(Figure
TIC Bus D-Channel Access Control
Applications of TIC Bus in IOM-2 Bus Configuration
ICC (7)
ICC (2)
ICC (1)
(Figure
ICC
.
.
.
59).
60). An access request to the TIC bus may either be generated
TIC-Bus
on IOM-2
SBCX-X
111
S-Interface
Description of Functional Blocks
NT
3081_09
U-Interface
PEB 3081
PEF 3081
2000-09-27