PEB3081FV14XP Lantiq, PEB3081FV14XP Datasheet - Page 155

PEB3081FV14XP

Manufacturer Part Number
PEB3081FV14XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3081FV14XP

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
Preliminary
4.3.7
Value after reset: 00
DCIC_CR
Write access to this register is possible if IOM_CR.CI_CS = 0 or IOM_CR.CI_CS = 1.
Read access to this register is possible only if IOM_CR.CI_CS = 1.
CS2-0 ... Channel Select for C/I0 Handler
This register is used to select one of eight IOM channels. If enabled, the data of the
C/I0 handler is connected to the corresponding C/I0 timeslot of that IOM channel.
The reset value is determined by the channel select pins CH2-0 which are mapped to
CS2-0.
Data Sheet
DCIC_CR - Control Register for CI0 Handler (IOM_CR.CI_CS=1)
7
0
H
0
0
0
155
0
Detailed Register Description
CS2-0
0
RD/WR (53)
PEB 3081
PEF 3081
2000-09-27