Z84C3006PEG Zilog, Z84C3006PEG Datasheet - Page 266

IC 6MHZ Z80 CMOS CTC 28-PDIP

Z84C3006PEG

Manufacturer Part Number
Z84C3006PEG
Description
IC 6MHZ Z80 CMOS CTC 28-PDIP
Manufacturer
Zilog
Type
Counter/Timer Circuit (CTC)r
Series
Z80r
Datasheets

Specifications of Z84C3006PEG

Frequency
6MHz
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
8mA
Operating Temperature
-40°C ~ 100°C
Package / Case
28-DIP (0.600", 15.24mm)
Processor Series
Z84C3xx
Core
Z80
Data Bus Width
8 bit
Maximum Clock Frequency
6 MHz
Operating Supply Voltage
0 V to 5 V
Maximum Operating Temperature
+ 100 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
Filter Terminals
SMD
Ic Generic Number
84C30
Operating Temperature Min
-40°C
Operating Temperature Max
100°C
Clock Frequency
6MHz
Rohs Compliant
Yes
Cpu Speed
6MHz
Digital Ic Case Style
DIP
No. Of Pins
28
Supply Voltage Range
5V
Operating Temperature Range
-40°C To +100°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Count
-
Lead Free Status / Rohs Status
 Details
Other names
269-3910
Z84C3006PEG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z84C3006PEG
Manufacturer:
ZILOG
Quantity:
1 980
Part Number:
Z84C3006PEG
Manufacturer:
Zilog
Quantity:
1 722
Part Number:
Z84C3006PEG
Manufacturer:
ZILOG
Quantity:
1 980
Part Number:
Z84C3006PEG
Manufacturer:
WSI
Quantity:
4 970
Part Number:
Z84C3006PEG
Manufacturer:
ZILOG
Quantity:
20 000
246
Operation:
Op Code:
Operands:
Description: This instruction provides for conditional branching to other segments of a
Condition Bits Affected: None
Example:
UM008005-0205
Z80 CPU
User’s Manual
If Z = 0, continue
If Z = 1, PC ← PC +e
JR
Z, e
program depending on the results of a test on the Zero Flag. If the flag is
equal to a 1, the value of the displacement e is added to the Program
Counter (PC) and the next instruction is fetched from the location
designated by the new contents of the PC. The jump is measured from the
address of the instruction Op Code and has a range of -126 to +129 bytes.
The assembler automatically adjusts for the twice incremented PC.
If the Zero Flag is equal to a 0, the next instruction executed is taken from
the location following this instruction. If the condition is met:
The Zero Flag is set and it is required to jump forward five locations
from address 300. The following assembly language statement is used
JR Z ,$ + 5
The resulting object code and final PC value is:
0
0
M Cycles
If the condition is not met;
M Cycles
1
3
2
e-2
0
1
JR Z, e
0
12 (4, 3, 5)
T States
T States
7 (4, 3)
0
0
28
4 MHz E.T.
4 MHz E.T.
3.00
1.75
Z80 Instruction Set

Related parts for Z84C3006PEG