Z84C3006PEG Zilog, Z84C3006PEG Datasheet - Page 214

IC 6MHZ Z80 CMOS CTC 28-PDIP

Z84C3006PEG

Manufacturer Part Number
Z84C3006PEG
Description
IC 6MHZ Z80 CMOS CTC 28-PDIP
Manufacturer
Zilog
Type
Counter/Timer Circuit (CTC)r
Series
Z80r
Datasheets

Specifications of Z84C3006PEG

Frequency
6MHz
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
8mA
Operating Temperature
-40°C ~ 100°C
Package / Case
28-DIP (0.600", 15.24mm)
Processor Series
Z84C3xx
Core
Z80
Data Bus Width
8 bit
Maximum Clock Frequency
6 MHz
Operating Supply Voltage
0 V to 5 V
Maximum Operating Temperature
+ 100 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
Filter Terminals
SMD
Ic Generic Number
84C30
Operating Temperature Min
-40°C
Operating Temperature Max
100°C
Clock Frequency
6MHz
Rohs Compliant
Yes
Cpu Speed
6MHz
Digital Ic Case Style
DIP
No. Of Pins
28
Supply Voltage Range
5V
Operating Temperature Range
-40°C To +100°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Count
-
Lead Free Status / Rohs Status
 Details
Other names
269-3910
Z84C3006PEG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z84C3006PEG
Manufacturer:
ZILOG
Quantity:
1 980
Part Number:
Z84C3006PEG
Manufacturer:
Zilog
Quantity:
1 722
Part Number:
Z84C3006PEG
Manufacturer:
ZILOG
Quantity:
1 980
Part Number:
Z84C3006PEG
Manufacturer:
WSI
Quantity:
4 970
Part Number:
Z84C3006PEG
Manufacturer:
ZILOG
Quantity:
20 000
194
Operation:
Op Code:
Operands:
Description: The contents of register r are rotated left 1-bit position. The content of bit 7
Condition Bits Affected:
UM008005-0205
Z80 CPU
User’s Manual
RLC
r
is copied to the Carry flag and also to bit 0. Operand r is specified as
follows in the assembled object code:
S is set if result is negative; reset otherwise
Z is set if result is zero; reset otherwise
H is reset
P/V is set if parity even; reset otherwise
N is reset
C is data from bit 7 of source register
CY
1
0
1
0
M Cycles
Register
7
0
0
D
H
A
B
C
E
L
2
r
0
0
0
1
0
RLC r
0
T States
8 (4, 4)
000
001
010
011
100
101
111
1
r
r
1
CB
4 MHz E.T.
2.00
Z80 Instruction Set

Related parts for Z84C3006PEG