ADUC7039BCP6Z-RL Analog Devices Inc, ADUC7039BCP6Z-RL Datasheet - Page 78

no-image

ADUC7039BCP6Z-RL

Manufacturer Part Number
ADUC7039BCP6Z-RL
Description
Flash 64k ARM7 Dual 16-Bit ADC LIN I.C.
Manufacturer
Analog Devices Inc
Series
MicroConverter® ADuC7xxxr
Datasheet

Specifications of ADUC7039BCP6Z-RL

Core Processor
ARM7
Core Size
16/32-Bit
Speed
20.48MHz
Connectivity
LIN, SPI
Peripherals
POR, Temp Sensor, WDT
Number Of I /o
6
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
3.5 V ~ 18 V
Data Converters
A/D 2x16b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 115°C
Package / Case
32-LFCSP
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Eeprom Size
-
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUC7039BCP6Z-RL
Manufacturer:
NS/国半
Quantity:
20 000
ADuC7039
High Voltage Interface Control Register
Name:
Address:
Default Value:
Access:
Function:
Table 56. HVCON MMR Write Bit Designations
Bit
7 to 0
Table 57. HVCON MMR Read Bit Designations
Bit
7 to 3
2
1
0
High Voltage Data Register
Name:
Address:
Default Value:
Access:
Function:
Table 58. HVDAT MMR Bit Designations
Bit
11 to 8
7 to 0
Description
Command with which the high voltage data, HVDAT[7:0], is associated. These bits are read-only and should be written as 0s.
0x00 = read back the high voltage register, HVCFG, into HVDAT.
0x02 = read back the high voltage status register, HVSTA, into HVDAT.
0x08 = write the value in HVDAT to the high voltage register, HVCFG.
High voltage data to read/write.
HVDAT
0xFFFF080C
Updated by kernel
Read/write
HVDAT is a 12-bit register that is used to hold data to be written indirectly to, and read indirectly from, the HVDAT,
HVSTA, HVCFG high voltage interface registers.
HVCON
0xFFFF0804
Updated by kernel
Read/write
This 8-bit register acts as a command byte interpreter for the high voltage control interface. Bytes written to this
register are interpreted as read or write commands to a set of two indirect registers related to the high voltage
circuits. The HVDAT register is used to store data to be written to, or read back from, the indirect registers.
Description
Reserved.
Transmit command to high voltage die status.
1 = command completed successfully.
0 = command failed.
Read command from high voltage die status.
1 = command completed successfully.
0 = command failed.
Bit 0 (read-only) busy bit. When user code reads this register, Bit 0 should be interpreted as the busy signal for the high
voltage interface. This bit can be used to determine if a read request has completed. High voltage (read/write) com-
mands as described in this table should not be written to HVCON unless busy = 0.
Busy = 1, high voltage interface is busy and has not completed the previous command written to HVCON. Bit 1 and Bit 2
are not valid.
Busy = 0, high voltage interface is not busy and has completed the command written to HVCON. Bit 1 and Bit 2 are valid.
Description
Command byte. Interpreted as
0x00 = read back high voltage register, HVCFG, into HVDAT.
0x02 = read back high voltage status register, HVSTA, into HVDAT.
0x08 = write the value in HVDAT to the high voltage register, HVCFG.
Other = reserved.
Rev. B | Page 78 of 92