IPR-FIR Altera, IPR-FIR Datasheet - Page 60

IP CORE Renewal Of IP-FIR

IPR-FIR

Manufacturer Part Number
IPR-FIR
Description
IP CORE Renewal Of IP-FIR
Manufacturer
Altera
Type
MegaCorer
Datasheets

Specifications of IPR-FIR

Software Application
IP CORE, DSP Filters And Transforms
Supported Families
Arria GX, Arria II GX, Cyclone, HardCopy, Stratix
Core Architecture
FPGA
Core Sub-architecture
Arria, Cyclone, Stratix
Rohs Compliant
NA
Function
Finite Impulse Response Compiler
License
Renewal License
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
4–18
Reset and Global Clock Enable Operations
Figure 4–14. Reset and Clock Enable Protocol
Single Rate Filter Timing Diagram
Figure 4–15. Single Channel, Single Rate (Parallel or MCV Single Cycle)
FIR Compiler User Guide
Figure 4–14
When the reset (reset_n) is applied to the filter, the ast_sink_ready and
ast_source_valid signals go low. At the next rising edge of the clock (clk) after
the reset is released, ast_sink_ready goes high indicating that the design is ready
to accept new data. This behavior is independent of the filter type and architecture
because there is a small FIFO in the Avalon-ST controller.
The global clock enable signal (where it exists) can also control when the FIR
MegaCore function is stalled. The Avalon-ST controller operates independent of the
global clock enable. The FIR is stalled as soon as the global clock enable goes low.
However, because of the internal buffering in the Avalon-ST controller, the
ast_sink_ready signal can go low in the following cycles. For the same reason,
when the global enable is high, ast_sink_ready may go high at a later cycle.
The ast_source_valid signal is produced by the Avalon-ST controller is therefore
independent of the global clock enable. When the available valid data is transferred,
and no more output data is available, it goes low until there is valid data to transfer.
Figure 4–15
implemented either in MCV architecture with a Clocks to Compute value of 1, or in
Parallel architecture.
shows the reset and clock enable operations.
shows the timing diagram of a single channel single rate FIR filter
© December 2010 Altera Corporation
Chapter 4: Functional Description
Timing Diagrams

Related parts for IPR-FIR