NT30-KBA04 Omron, NT30-KBA04 Datasheet - Page 84

no-image

NT30-KBA04

Manufacturer Part Number
NT30-KBA04
Description
ANTI GLARE COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Processing Functions
Function Outline
Relationship with Other Elements
2-3-3 Bit Memory Tables
Memory Tables
Character string memory tables have no data processing function.
• When character string display is used, the contents of character string memory
• When alarm list or alarm history is used, the contents of the character string
• When a lamp’s guide character is made into a character string display, the con-
• When a touch switch’s guide character is made into a character string display,
• When character string input is used, character strings can be input into the
• When the touch switch copy setting function is used, the contents of a charac-
• By operation of the PT status control area. data can be copied between
• If the contents of character string memory tables are changed by operation at
Bit memory tables are internal memories for bit data.
They are allocated to a bit at the host to monitors a bit, and can execute a specific
function in accordance with the status of that bit.
Bit memory tables are assigned bit memory table numbers so that they can be
managed and designated individually.
Bit memory tables have the following functions.
Screen Changeover Function
When the host bit to which a bit memory table is allocated changes status from 0
(OFF) to 1 (ON), the screen whose screen number is set in the bit memory table
is displayed.
If the allocated bits of multiple bit memory tables come ON at the same time, the
bit memory table with the smallest number takes priority.
Alarm List/History Function
When the status of the host bit to which a bit memory table is allocated changes
to 1 (ON), the contents of the character string memory table (message), and
image/library data set for that bit memory table are displayed (this is the alarm
list function). In order to use the alarm list function, it must be registered for the
screen in advance. If more than one bit memory table is set for the alarm list func-
tion, those with smaller bit memory table numbers are given display priority,
therefore it is possible to assign an order or priority to displayed messages.
If registration in the alarm history is designated, the time when the status of the
host bit to which the bit memory table is allocated changes to 1 (ON) is recorded
in the alarm history (alarm history function).
tables can be displayed in real time as character strings (page 138).
memory table can be displayed as a message (page 173).
tents of a character string memory table can be displayed as guide characters
in real-time (page 103).
the contents of a numeral memory table can be displayed as guide characters
in real-time (page 110).
character string memory table from the screen of the PT (page 201). It is also
possible to input character strings from a bar code reader connected to the PT.
ter string memory table can be copied (page 126).
memory tables from the host (page 46).
the PT, the change is notified to the PT status notify area (page 55).
Screen number 11
displayed
Screen number 10
Screen number 11
Screen number 12
No. 1
No. 2
No. 3
Section
Bit
0
0
0
← 1 (ON)
PC
2-3
75