NT30-KBA04 Omron, NT30-KBA04 Datasheet - Page 251

no-image

NT30-KBA04

Manufacturer Part Number
NT30-KBA04
Description
ANTI GLARE COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Sounding the Buzzer
Stopping the Buzzer
Numeral Memory Tables
Used with the Clock
Function
2-16-6 Clock Function
242
Special Functions
Reference:
S When the battery voltage becomes low, the time data cannot be retained by
S The PT does not allow display and setting of clock data with the clock function
S No calendar or time data is set on shipment from the factory.
For example, if the continuous buzzer and short intermittent buzzer are speci-
fied together, the continuous buzzer sounds.
Except the case the buzzer is set not to sound at all, the buzzer automatically
sounds when an error occurs at the PT. Apart from this, there are the following
two methods for sounding the buzzer.
Sounding The Buzzer by Control from The Host
The buzzer can be sounded from the host by operating the PT status control
area during operation (page 280).
A Method to Use The buzzer Screen Attribute
By setting a Buzzer screen attribute when creating screen data with the Support
Tool, the buzzer can be sounded when the created screen is displayed (page
280).
When the buzzer is sounding, it can be stopped in the following ways.
• By operating the PT status control area from the host (page 282).
• By displaying a screen for which no buzzer attribute is set (page 281).
• By pressing a touch key assigned the buzzer stop function (page 283).
By creating a touch switch assigned the buzzer stop attribute (the [
control) on a screen for which a buzzer attribute is set, the buzzer can be
stopped by pressing this switch.
The PT has a clock function for setting and displaying the date and time. The
clock function is backed up by the built-in battery of the PT.
The PT uses numeral memory tables No. 247 to 255 for clock data.
As shown in the table below, numbers 247 to 253 are for display and reading
only, and numbers 254 and 255 are for time setting.
Numbers 247 through 253 store clock data which is updated by the internal clock
of the PT. This data cannot be rewritten by the host.
Display/
reading
only
only
2. Short intermittent buzzer
3. Long intermittent buzzer
turning off the power to the PT, or resetting the PT, consequently the clock
function will not operate correctly.
from the Support Tool. To set the time, use System Menu or numeral memory
table operations.
Func-
tion
di
However, when this method is used, the buzzer will not be stopped unless
the bits for all three buzzer types — continuous, short intermittent, and long
intermittent — are set to 0 (OFF).
y
Numeral
memory
table
247
248
249
250
251
252
253
Digit position
Information
Day of week 00 to 06 See below.
Second
Minute
Month
Hour
Date
Year
00 to 59
00 to 59
00 to 23 24-hour system
01 to 31
01 to 12
00 to 99 Last 2 digits of the year
Value
Section
] input key –
Remarks
2-16