NT30-KBA04 Omron, NT30-KBA04 Datasheet - Page 291

no-image

NT30-KBA04

Manufacturer Part Number
NT30-KBA04
Description
ANTI GLARE COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Setting
Operation
Stopping the Buzzer by the Operation at the PT Control Area
282
Buzzer, Backlight, and Display Control
15
14
13
12
11
Stopping the buzzer
10
0
Reference: If more than one bit among the bits indicated above is 1 (ON) at the same time,
9
8
7
6
only one type of buzzer sounds according to the priority: continuous buzzer >
short intermittent sound > long intermittent sound. To stop the buzzer when it is
sounding, set 0 (0) for all bits indicated above; setting 0 (OFF) only for the bit cor-
responding to the type of buzzer sound may not stop the buzzer.
5
This method allows the operator to stop the buzzer at any required time.
The PT status control area must be allocated to a word in the host and, accord-
ingly, there are no special settings required for the control of buzzer.
The bit for controlling the PT status (PT status control bit) is provided at the fourth
word (n + 3 words) from the beginning of the PT status control area.
To stop the buzzer during operation of the PT, operate the PT status control area
as indicated below.
Set 0 (OFF) for all of the following bits in the fourth word (n + 3 words) from the
beginning of the PT status control area.
• Continuous sound:
• Short intermittent sound:
• Long intermittent sound:
4
3
2
PT
1
0
0
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bits 2 and 3 are not used when the PT is in NT30/620
compatible mode.
Screen display
Processing priority registration (for NT link (1:N))
Continuous buzzer
Intermittent buzzer (short)
Display history initialization
Not used
Intermittent buzzer (long)
Backlight mode
Screen printing
PT window opening
Numeral/character string input
PT screen switching
Memory table copy execution
Memory table copy type
Alarm history initialization
Not used
PT status control area
Screen switch setting
Copy memory
table setting
PT status control setting
Reserved for system use
Bit 13
Bit 12
Bit 9
Controlled Item
PC
← Control data
Registered
Performed
Performed
Performed
Performed
Performed
Sounded
Sounded
Sounded
Disabled
Disabled
Disabled
Numeral
1 (ON)
Lit
Section
Always 0
Always 0
Character string
Not performed
Not performed
Not performed
Not performed
Not performed
Canceled
Stopped
Stopped
Stopped
Flashing
Enabled
Enabled
Enabled
0 (OFF)
3-2