Datasheets

Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Setting
Operation
3-4-3 Disabling/Enabling the Opening of a Window
Controlling the Window by Operation at the PT Status Control Area
Display and Control of Windows
15
14
13
12
11
10
0
Reference: Display status of the window is always written to a window control area during the
9
8
7
6
operation of the PT.
5
(such as system menu or error screen) is displayed, the window is automatically
closed, but the window screen number retains the existing value.
The value in a window control area is effective only when the window is dis-
played.
Opening of a window by operation at the PT can be enabled/disabled by using
the method indicated below.
Controlling the window by operation at the PT status control area
This method allows the opening of a window by operation at the PT to be dis-
abled. (Even if the opening of a window is disabled, it is possible to close the
window by operation at the PT, or to move a window by a touch switch operation
which has window move function. Also, opening/closing/moving a window by
operation of the window control area is always possible.)
The PT status control area must be allocated to a word in the host, accordingly,
no special settings are required for the control of a window.
The bit for controlling the PT status (PT status control bit) is provided at the fourth
word (word n + 3) from the beginning of the PT status control area.
To disable the opening of a window by operation at the PT during the operation of
the PT, operate the PT status control area as indicated below.
Set 1 (ON) for bit 6 in the fourth word (word n + 3) from the beginning of the PT
status control area.
4
3
2
1
0
0
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bits 2 and 3 are not used when the PT is in NT30/620
compatible mode.
Screen display
Processing priority registration (for NT link (1:N))
Continuous buzzer
Intermittent buzzer (short)
Display history initialization
Not used
Intermittent buzzer (long)
Backlight mode
Screen printing
PT window opening
Numeral/character string input
PT screen switching
Memory table copy execution
Memory table copy type
Alarm history initialization
Not used
Controlled Item
Registered
Performed
Performed
Performed
Performed
Performed
Sounded
Sounded
Sounded
Disabled
Disabled
Disabled
Numeral
1 (ON)
Lit
Section
Always 0
Always 0
Character string
Not performed
Not performed
Not performed
Not performed
Not performed
Canceled
Stopped
Stopped
Stopped
Flashing
Enabled
Enabled
Enabled
0 (OFF)
305
3-4