NT30-KBA04 Omron, NT30-KBA04 Datasheet - Page 239

no-image

NT30-KBA04

Manufacturer Part Number
NT30-KBA04
Description
ANTI GLARE COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Opening windows by
setting screen attribute
Opening/Closing and
moving a window by
touch switch operation
2-15-3 Window Screens and Display Elements
2-15-4 Opening/Closing and Moving a Window
230
Window Function
Reference:
Reference: With PT, up to 3 windows can be opened at the same time. (1 global window and 2
local windows)
S Elements that project beyond the window area will not be displayed when the
S While a window is open, display processing is slightly delayed.
Opening, closing or moving a window can be performed by the following opera-
tions.
• Setting the screen attribute (A window pops up when the screen is displayed.)
• Touch switch operation (using input key-window/keyboard or window move
• Window control area operation from the host.
It is possible to specify the window type which is used for opening a window,
therefore, the same window can be opened as a global window or as a local win-
dow. However, it is not possible to display the same window multiply using both
window types.
Using the window function, window can be created in any of the user screens,
numbered 1 to 3999 (a screen for which a window is registered is called a win-
dow screen)
When a screen is registered as a window screen, the window area must be spe-
cified to set the size of the window. The window is always displayed at the win-
dow area size.
In addition, window position can be specified for the screen attribute, touch
switch property or window control area when displaying the window. The window
position can be moved later by touch switch operation or by a specification at
window control area.
With PT, all elements other than thumbwheel switch can be registered.
However, only one temporary input field (numeral or string input) can be regis-
tered for a window.
By setting the background color screen attribute for a window screen, the win-
dow can be displayed with a different background color than that of the base
screen.
Window can be controlled by the following operations.
When creating a screen using the Support Tool, up to two windows can be speci-
fied as a pop-up window which is displayed at the same time the screen is
opened.
By this method, window is displayed at the position which was specified when
window screen was created. This kind of window is a local window. For details of
the setting, refer to Screen Attributes (page 39)
To create a pop-up window/keyboard touch switch on a screen or a window en-
ables to open/close specified window.
window opens.
function touch switch)
Switch screen
Window
opens
Section
2-15

Related parts for NT30-KBA04