4-3
4-3-1 PT Memory Read Command
Command
Format
Response
Format
Function
Commands/Responses
Commands/Responses
This section describes the commands used with the memory link and their re-
sponses.
m
c
l
s1, s2 :
c
l
d1
s
• Reads the contents of the specified number of words from the specified word of
• Used to read the statuses of the PT notify area, window control area, lamps,
1
1
1
1
1
, l
, l
the PT memory.
touch switches and bit memory tables allocated to the PT memory, and the
contents of numeral and character string memory tables.
, s
1
to c
to c
[ESC]
2
2
to d1
d11
* *
2
1B
Data of 1 word
4
4
:
:
:
:
:
:
m
, ..., dn
52
R
[ESC]
1B
Check sum present/absent (1 BCD digit)
0 : Absent
1 : Present
8 : Absent (1 word read)
9 : Present (1 word read)
First word number read (4 BCD digits)
0000 to 9999
Number of read words (2 BCD digits)
00
01 to 99
When m is 8 or 9, omit this setting.
Check sum (2 hexadecimal digits)
When m is 0 or 8, omit this setting.
First word number read (4 BCD digits)
0000 to 9999
Number of read words (2 BCD digits)
01 to 50 :
Contents of the read words (1 to 4 hexadecimal digits)
0 to FFFF
Since initial zeroes are omitted, there may be less than 4 digits.
Individual words of data are delimited by commas.
Check sum (2 hexadecimal digits)
This is always added.
d1m
* *
4D
1
M
to dn
(l1)
* *
52
R
* *
2C
c1
m
,
:
H
(l2)
* *
4D
M
* *
c2
:100 words
: 1 to 99 words
1 to 50 words
(s1)
* *
* *
m
* *
dn1
* *
c3
Data of 1 word
(s2)
* *
* *
c1
* *
(Sent from Host to PT)
c4
[CR]
* *
0D
c2
dnm
* *
* *
l1
* *
c3
* *
* *
* *
s1
l2
* *
c4
Section
* *
s2
[CR]
0D