NT30-KBA04 Omron, NT30-KBA04 Datasheet - Page 330

no-image

NT30-KBA04

Manufacturer Part Number
NT30-KBA04
Description
ANTI GLARE COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Input of Numeric Values and Character Strings
the input. When the input is confirmed, the input numeric value is written to the
numeral memory table and the occurrence of a change in the contents of the
numeral memory table is notified to the PT status notify area (page 55).
The ENT key and the
• ENT key
Upper and Lower Limit Checks
The PT checks whether inputs are within the specified range to prevent the sys-
tem from being adversely affected by the input of incorrect values. When a nu-
meric value has been input in a numeral input field, the PC checks it against the
upper and lower limit values when the value is confirmed.
Initial Operation of Input Keys
How the sign () key, the decimal point (.) key, and alphabetic letter (A to F) keys
operate in the initial input (the first input after the screen is displayed or after the
confirmation of the previous input) is described below.
• Sign () key:
• Decimal point (.) key:
• Alphabetic letter (A to F) key:
Input Example
In actual numeric input, the input numeric value changes as shown below.
Input example 1)
Decimal display, signed, 4 digits in integer part, 3 digits in decimal fraction part
Input example 2)
Decimal display, unsigned, 4 digits in integer part, 3 digits in decimal fraction part
Order
When more than one numeric key type numeral setting input field exits on the
screen, the input objective shifts to the next input field when the input is con-
firmed. The input objective shifts in the order specified by the Support Tool.
Even when more than one numeric key type numeral setting input field exits on
the screen, the input objective does not shift after the confirmation of the input.
The display is cleared to 0.
The display is cleared to 0 and the input starts in the decimal fraction part. If the
number of digits of the decimal fraction part is 0, numeric input is not the input
for the decimal fraction part.
In decimal input:
In hexadecimal input:
Initial value
1
2
3
4
5
6
key
Key
B
1
5
2
±
4
Displayed
numeric
–0152.000
–1524.000
0000.000
0001.000
0015.000
0152.000
0152.000
value
key differ from each other in the following respects.
The input is disregarded, and the buzzer sounds
three times.
The input alphabetic letter is displayed.
Order
10
12
13
11
7
8
9
Key
A
1
5
2
7
.
Displayed
–1524.000
–1524.000
–1524.100
–1524.150
–1524.152
–1524.527
–1524.527
numeric
value
Order
14
15
16
17
18
19
20
Section
Key
7
2
±
±
1
.
Displayed
numeric
–0001.000
0000.000
0000.700
0000.720
0000.720
0000.000
0001.000
value
321
3-7

Related parts for NT30-KBA04