Device Monitor Function
Remove trouble execution
fails.
(when clearing an error from
error log screen)
Connection failed.
(when starting the Device
Monitor function)
Set Comm. Method to NT
Link (1:1 or 1:N)
(when the Device Monitor
menu is being displayed)
(Serial port reception error
screen being displayed)
Error
The cause of the PC error
has not been eliminated.
The Device Monitor function
was called when the PT was
not connected to a PC that
supports Device Monitor.
The communications protocol
set at the PT is not 1:1 NT
Link or 1:N NT Link.
The connecting cable is
disconnected or faulty.
Probable cause
Eliminate the cause of the error that you are trying to
clear. For details, refer to the PC’s operation manual.
Check the model of the PC that is connected. (Refer to
2-17-1 Compatible Systems for a table of PCs that
support the Device Monitor function.)
Check the memory switches (fourth screen) and set the
connected PC’s serial port protocol to 1:1 NT Link or
1:N NT Link. Set the same protocol in the PC.
Verify the connection between the PT and PC. For
details, refer to section 7 of the Setup Manual .
Remedy
Section
2-17