Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Touch Switches
The attributes for the window key are as follows.
The window behaves as follows according to the settings for Action Type and
Replace Local Windows.
Behavior According to The action Type
Open: Opens the specified window by the specified type (local 1 or local 2).
Close: Closes the specified window of the specified type (local 1 or local 2).
Toggle: Opens or closes the specified window of the specified type (local 1 or
Behavior According to The Replace Local Window
Check mark:
Settings
Screen No.
Window Position
Action Type
Replace Local
Window
Local 1
(Keyboard)
Local 2
X
Y
Whether or not the window is actually opened depends on the display
status and the setting for Replace Local Window.
The window is displayed at the position which is specified with the Win-
dow Position setting.
If the other window of the same type is already opened, the behavior is
determined according to the setting for Replace Local Window.
If the specified window does not exist, no operation is performed.
When the close window key is pressed, the specified window which is
presently displayed by the specified type is closed.
If the specified window is not displayed by the specified type, no opera-
tion is executed.
local 2).
If the specified window is not displayed by the specified type, the speci-
fied window is opened in the same way as the Open window key.
Whether or not the window is actually opened depends on the display
status and the setting for Replace Local Window.
The window is displayed at the position which is specified with the Win-
dow Position setting.
If the other window of the same type is already opened, the behavior is
determined according to the setting for Replace Local Window.
If the specified window does not exist, no operation is performed.
If the specified window is already displayed by the specified type, the
window is closed in the same way as Close window key.
If the other window of the same type is already displayed, the
displayed window is closed first, and then the specified window
is opened.
Check this attribute when the local window 1 is to be
controlled.
S Specify the screen number of the window to be
Check this attribute when the local window 2 is to be
controlled.
S Specify the screen number of the window to be
X coordinate of bottom-left corner (multiple of 20)
Y coordinate of bottom-left corner (multiple of 20 - 1)
Controlling method of the window
Specify the behavior of the window when the other
window of the same type (Local 1/Local 2) is already
opened.
controlled.
controlled.
NT31/NT31C: 0 to 300
NT631/NT631C: 0 to 620
NT31/NT31C: 19 to 239
NT631/NT631C: 19 to 479
Open/Close/Toggle
Check mark (replace)/No check mark (no replace)
1 to 3999
1 to 3999