NT30-KBA01 Omron, NT30-KBA01 Datasheet - Page 443

no-image

NT30-KBA01

Manufacturer Part Number
NT30-KBA01
Description
CHEMICAL RESISTANT COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA01

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Compatibility with Screen Data of Other PT Models
Differences between PT models without the -V1 Suffix and PT
models with -V1
434
Drawing
order of
objects
PT status
notify area
Window
control area
Item
PT status notify bits
None
Word m
Word m+1
Word
15
14
13
12
10
11
9
8
7
6
Display
Word
Bottom
Top
PT operation status
Not used
Battery
Screen switch strobe
Numeral setting strobe
Character string setting strobe
Not used
Not used
Printer operating status
Backlight status
15
NT31/NT31C and NT631/NT631C (without -V1)
14
Notified Information
13
Image/library lamp
Alarm list/history frame
Temporary input
String input
Thumbwheel
Numeral input
Trend graph
Broken line graph
Bar graph
Numeral display
String display
Fixed display
Lamp
Touch switch
Image/library
Screen background
12
PT status notify bits
Numeral/character string memory table number
(BCD or hexadecimal 4 digits)
11
10
9
Object Types
8
Bit
7
Run
Low
ON
ON
ON
Printing
OFF
6
1 (ON)
5
0
4
Always 0
Always 0
Always 0
0
3
Stop
Normal
OFF
OFF
OFF
Stopped
Lit/flashing
2
0 (OFF)
0
1
0
PT status notify bits
Word k
Word k+1
Word k+2
Word k+3
Word k+4
Word k+5
Word k+6
Word k+7
Word k+8
Word
Word m
Word m+1
15
14
13
12
11
10
9
8
7
6
5
4
3
Display
Word
Word
Bottom
Top
PT operation status
Not used
Battery
Screen switch strobe
Numeral setting strobe
Character string setting strobe
Not used
Not used
Printer operating status
Backlight status
Global window open status
Local window 1 open status
Local window 2 open status
15
15
NT31/NT31C and NT631/NT631C (with V1)
14
14
Notified Information
13
13
Image/library lamp
Alarm list/history frame
Temporary input
String input
Thumbwheel
Numeral input
Trend graph
Broken line graph
Analogue meter
Bar graph
Numeral display
String display
Fixed display
Lamp
Touch switch
Image/library
Screen background
12
12
PT status notify bits
Numeral/character string memory table number
(BCD or hexadecimal 4 digits)
X coordinate (4-digit BCD or hexadecimal)
Y coordinate (4-digit BCD or hexadecimal)
X coordinate (4-digit BCD or hexadecimal)
Y coordinate (4-digit BCD or hexadecimal)
X coordinate (4-digit BCD or hexadecimal)
Y coordinate (4-digit BCD or hexadecimal)
Screen No. (4-digit BCD or hexadecimal)
Screen No. (4-digit BCD or hexadecimal)
Screen No. (4-digit BCD or hexadecimal)
11
11
10
10
9
Object Types
9
Local window1
Local window2
Global window
Global window
Global window
Local window1
Local window1
Local window2
Local window2
8
8
Bit
Bit
7
7
Run
Low
ON
ON
ON
Printing
OFF
Open
Open
Open
6
6
1 (ON)
5
5
Appendix B
4
4
Always 0
Always 0
Always 0
3
3
Stop
Normal
OFF
OFF
OFF
Stopped
Lit/flashing
Close
Close
Close
2
2
0
0 (OFF)
1
1
0
0
0
0

Related parts for NT30-KBA01