NT30-KBA01 Omron, NT30-KBA01 Datasheet - Page 178

no-image

NT30-KBA01

Manufacturer Part Number
NT30-KBA01
Description
CHEMICAL RESISTANT COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA01

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Graphs
Reference: The retention of data by the data logging function remains effective until any of
the following operations is performed.
S The power to the PT is turned OFF.
S The PT is reset.
S All the screen data is transmitted.
S Data is transmitted in screen units.
When operation is stopped, for example by displaying the System Menu, sam-
pling is also stopped even if the background function is being used; it is restarted
when operation is restarted (the data is retained and recording starts from the
data following the last data).
Data is recorded as described below depending on whether or not the data log-
ging function and background function are used. The PT will start drawing the
trend graph again when it is switched to a screen containing the trend graph from
another screen, so use a touch switch that controls the trend graph if you want to
display the previous data.
When Neither The Data Logging Function or Background Function Is Used
When The Data Logging Function Is Used and The Background Function
Is Not Used
When Both The Data Logging Function and The Background Function Are
Used
Trend graph screen
Trend graph screen
Trend graph screen
Data logging
performed
Screen
switching
Screen
switching
No data logging during this
period
Screen
switching
Data logging performed continually
Data logging not performed
Other screen
Other screen
Other screen
Return
Return
(trend graph drawing restarts)
Return
Trend graph screen
Trend graph screen
Trend graph screen
Data logging
performed
Section
2-10