NT30-KBA01 Omron, NT30-KBA01 Datasheet - Page 313

no-image

NT30-KBA01

Manufacturer Part Number
NT30-KBA01
Description
CHEMICAL RESISTANT COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA01

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
304
Display and Control of Windows
15
14
0
13
12
11
10
0
9
Reading Out The Opening/Closing Status of a Window
The bit for notifying the PT status (PT status notify bit) is provided at the second
word (word m + 1) from the beginning of the PT status notify area.
Check the bits from 3 to 5 of the second word (word m + 1) from the beginning of
the PT status notify area with the program in the host.
The status of each bit and the correspondence to a window are as follows.
By checking the status of the bit shift, it is possible to know the occurrence of
opening/closing of the window.
Notification of Window Screen Number and Coordinates
In the window control area, the following three words are provided for each glob-
al window, local window 1 and local window 2.
With the program in the host, read out window screen number, X coordinate and
Y coordinate in a window control area which corresponds to the window of which
display status is to be checked.
The window screen number and bottom left X, Y coordinates of the window
which is presently displayed on the PT are stored in 4-digit BCD or hexadecimal.
Which of BCD or hexadecimal is used is determined by the setting of Numeral
Storage Type in PT Configuration at the Support Tool.
When the window is not displayed, 0000 is stored in window screen number. In
the case of global window, however, when the screen other than user screen
0
8
7
Bit
Word
k
k+1
k+2
k+3
k+4
k+5
k+6
k+7
k+8
5
4
3
6
15
5
4
14
Global window open status
Local window 1 open status
Local window 2 open status
3
13
12
2
0
X coordinate (4-digit BCD or hexadecimal)
Y coordinate (4-digit BCD or hexadecimal)
X coordinate (4-digit BCD or hexadecimal)
Y coordinate (4-digit BCD or hexadecimal)
X coordinate (4-digit BCD or hexadecimal)
Y coordinate (4-digit BCD or hexadecimal)
Screen No. (4-digit BCD or hexadecimal)
Screen No. (4-digit BCD or hexadecimal)
Screen No. (4-digit BCD or hexadecimal)
11
1
0
10
0
0
Name
15
13
12
10
11
7
6
5
4
3
Bit
9
PT operation status
Battery status
Screen switch strobe
Numeral setting strobe flag
Character string setting strobe flag
Printer operating status
Backlight status
Global window open status
Local window1 open status
Local window2 open status
8
Notified Information
7
6
5
Open
Open
Open
4
3
1 (ON)
Printing
1 (ON)
Open
Open
Open
2
Run
Low
Off
1
Lit/Flashing
0
Stopped
0 (OFF)
Normal
Closed
Closed
Closed
Section
Stop
Bit
Closed
Closed
Closed
Global window
Local Window1
Local Window2
0 (OFF)
3-4

Related parts for NT30-KBA01