NT30-KBA01 Omron, NT30-KBA01 Datasheet - Page 112

no-image

NT30-KBA01

Manufacturer Part Number
NT30-KBA01
Description
CHEMICAL RESISTANT COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA01

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Function Outline
Common Attributes
2-6
Restrictions
Lamps
Lamps
Lamps are graphics that change in accordance with the status of a set bit. Lamps
are classified into the two major categories indicated below.
Normal (Standard) Lamps
Normal (standard) lamps change the display status (OFF/ON/flashing) of fixed
display graphics.
Image/Library Lamps
Image/library lamps display different graphics (image/library data) in the ON and
OFF statuses.
Lamps are arranged and set on the screen when creating screen data with the
Support Tool.
• A maximum of 256 lamps can be registered for one screen. For an overlapping
• When polygons are used as the display graphics for normal (standard) lamps,
• Image/library lamps are subject to the maximum simultaneous display restric-
• When library data is displayed with an image/library lamp, if the library data
• If no data is registered for the specified image/library lamp code, nothing will be
• Among lamps, the display order is determined by the order in which the lamps
The common attributes vary widely according to the type of lamp, therefore they
are described separately for each case.
screen comprising 8 child screens, the maximum is 1024.
one polygon can be given up to 255 vertices.
tion imposed on image and library data. This means that a maximum total of
256 image/library lamps and image and library data can be displayed on one
screen. For an overlapping screen comprising 8 child screens, the maximum is
1024.
projects outside the screen area, nothing is displayed. Usually, the Support
Tool ensures that the data does not project out of the screen area.
displayed.
were created. However, this order among lamps can be changed with the Sup-
port Tool.
There is no restriction on the number of lamps that can be registered for one
screen data file: any number can be registered as long as the data file ca-
pacity is not exceeded. However, if a large number of elements are regis-
tered, check that the restrictions on element display are complied with by
referring to Display Restrictions (page 425).
OFF status
OFF status
ON
ON
ON
Host
Host
ON status
ON status
Section
103
2-6

Related parts for NT30-KBA01