NT30-KBA01 Omron, NT30-KBA01 Datasheet - Page 268

no-image

NT30-KBA01

Manufacturer Part Number
NT30-KBA01
Description
CHEMICAL RESISTANT COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA01

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Changing Binary PVs
and Forcing Bit Status
Device Monitor Function
Reference:
Reference: The status of bits in the EM Area (EM or banks EM0 through EMF) cannot be
1, 2, 3...
S Monitoring will stop in the row while the popup input window is being dis-
S No other operations can be performed while the popup input window is being
forced.
Use the following procedure to change the status of bits in the monitored word.
This procedure cannot be used to change the PVs of timers or counters.
At the same time, the binary PV field will be displayed in reverse video.
1. Press the binary PV table cell in the desired row. (Pressing the cell won’t
2. Press the Left and Right Arrow Keys to move the cursor to another bit.
3. Specify the bits, value or forced status with the following touch switches on
4. Press the Write touch switch. The new bit values and/or forced status will be
played. Monitoring will continue in the other rows and any changes in those
words will appear on the screen.
displayed on the screen. (The PT can be controlled from the PC if the PT is
operating.)
If the Back touch switch is pressed before the Write touch switch, the input
will be cancelled and the PT will restart monitoring with the original PV.
have any effect if a word isn’t being displayed in the row.)
The following popup input window will be displayed.
the popup input window.
If the Clear touch switch is pressed, the new bit settings will be be cancelled
and the display will be returned to the status it had before the popup input
window was opened or just after the data was written.
written to the word in the specified row, the hexadecimal PV, binary PV, and
Cannot write in RUN mode
Write-protected memory
Set the bit to 1 (ON).
Set the bit to 0 (OFF).
Force-set the bit.
Force-reset the bit.
NT31/NT31C input window
NT631/NT631C input window
Error message
The cursor is located at the bit that is not displayed in reverse video.
0
Action
1 1 1 1 1 1 1 0 1 0 1 1 1 0 0
Attempted to write to a PC in RUN mode.
Attempted to write to a read-only or
write-protected area.
1
0
Set or Force-set
Reset or Force-reset
Touch switch
Probable cause
Section
1
0
S
R
Bit display
2-17
259

Related parts for NT30-KBA01