NT30-KBA01 Omron, NT30-KBA01 Datasheet - Page 356

no-image

NT30-KBA01

Manufacturer Part Number
NT30-KBA01
Description
CHEMICAL RESISTANT COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA01

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Operation
Display and Setting of Calendar Clock
PT Status Control (word n + 3)
15
14
13
12
11
10
0
9
8
7
6
5
In the PT status control area, the following areas are provided to be used for
copying the data between memory tables.
• Second word from the beginning (word n + 1)
• Third word from the beginning (word n + 2)
• Fourth word from the beginning (word n + 3)
(n: First word number in the PT status control area)
The operation for setting the date and time data is described below.
The following explains the operation for copying the numeric value from copy
source numeral memory table A to copy destination numeral memory table No.
254 and from copy source numeral memory table B to copy destination numeral
memory table No. 255. The numeric values in numeral memory tables A and B
are stored in BCD.
n
n + 1
n + 2
n + 3
n + 4
Word
4
Copy source memory table No.
Copy destination memory table No.
Memory table type (bit 2) and PT status control bit specifying the execution
of copying (bit 3)
3
15
2
Copy destination memory table No. (4-digit BCD or hexadecimal)
14 13 12 11 10 9
Copy source memory table No. (4-digit BCD or hexadecimal)
1
0
0
Bit
Screen No. (4-digit BCD or hexadecimal)
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bits 2 and 3 are not used when the PT is in NT30/620
compatible mode.
Screen display
Processing priority registration (for NT link (1:N))
Continuous buzzer
Intermittent buzzer (short)
Display history initialization
Not used
Intermittent buzzer (long)
Backlight mode
Screen printing
PT window opening
Numeral/character string input
PT screen switching
Memory table copy execution
Memory table copy type
Alarm history initialization
Not used
Reserved for system use
PT status control bits
The configuration and functions of these words are
different when the PT is in NT30/620 compatible mode.
8
7
Controlled Item
6
5
4
3
2
1
0
Registered
Performed
Performed
Performed
Performed
Performed
Sounded
Sounded
Sounded
Disabled
Disabled
Disabled
Numeral
1 (ON)
Screen switch setting
PT status control
Bit
Lit
Section
Copy memory
table setting
Always 0
Always 0
Character string
Not performed
Not performed
Not performed
Not performed
Not performed
Canceled
Stopped
Stopped
Stopped
Flashing
Enabled
Enabled
Enabled
0 (OFF)
3-10
347

Related parts for NT30-KBA01