NT30-KBA01 Omron, NT30-KBA01 Datasheet - Page 273

no-image

NT30-KBA01

Manufacturer Part Number
NT30-KBA01
Description
CHEMICAL RESISTANT COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA01

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
2-17-7 Using the Error Log Screen
264
Device Monitor Function
Reference:
S Monitoring will stop in a table while the popup input window is being displayed
S No other operations can be performed while the popup input window is being
The error log screen reads the error log in the PC (the errors that have occurred
in the PC) and lists the errors in order of their priority. It is also possible to clear
the highest priority error.
2. Press the Up and Down Arrow Keys (Y and B) to select the desired data
3. Specify the address by pressing the Increment and Decrement Keys (+ and
4. Press the Write touch switch. The PT will begin monitoring the range of
for that table. (With the NT631/NT631C, monitoring will continue in the other
table and any changes in those words will appear on the screen.)
displayed on the screen. (The PT can be controlled from the PC if the PT is
operating.)
* The number of EM banks depends upon the PC being used. The PT will display
only those EM banks available in the connected PC.
area. The following table shows the order in which the data areas appear
when the Down Arrow Key is pressed. (The data areas appear in the oppo-
site order when the Up Arrow Key is pressed.)
Select clear for the data area to clear the table to all spaces.
–) on the word address’s thumbwheel switch. (This step isn’t necessary if
you are clearing the table.)
The digit will be incremented or decremented by 1 each time that you press
the Increment or Decrement Key.
The table containing the specified word will be displayed. Each table con-
tains either 25 words (NT31/NT31C) or 50 words (NT631/NT631C).
words that contains the specified word and the popup input window will be
closed. (The table will be cleared if clear was selected for the data area.)
If the specified word address is not valid, an error message will be displayed
in the lower-left corner of the screen and the buzzer will sound. (This buzzer
sound can be disabled with the PT’s touch switch sound setting.) In this
case, check the valid range of the data area in the connected PC and enter
the word address again. The error message will be cleared when a valid
word address is entered.
If the Back touch switch is pressed before the Write touch switch, the input
will be cancelled and the PT will return to monitoring the original word ad-
dresses.
CS1, C200HX/HG/HE (-Z) DM → CH → TIM → CNT → HR → AR → WR →
C200HS, CPM1, CPM2A,
CPM2C, CQM1, SRM1
CQM1H
PC model
EM* → EM0* → ... → EMF* → clear → (repeat
from DM)
DM → CH → TIM → CNT → HR → AR → LR →
clear → (repeat from DM)
DM → CH → TIM → CNT → HR → AR → LR →
EM* → EM0* → clear → (repeat from DM)
Data area order
Section