Specifications of D6417709SF167BV

Core Processor
SH-3
Core Size
32-Bit
Speed
167MHz
Connectivity
EBI/EMI, FIFO, IrDA, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
96
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.75 V ~ 2.05 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
208-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D6417709SF167BV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
10.2.5
The individual memory control register (MCR) is a 16-bit readable/writable register that specifies
RAS and CAS timing for synchronous DRAM (areas 2 and 3), specifies address multiplexing, and
controls refresh. This enables direct connection of synchronous DRAM without external circuits.
MCR is initialized to H'0000 by a power-on reset, but is not initialized by a manual reset or in
standby mode. Bits TPC1–TPC0, RCD1–RCD0, TRWL1–TRWL0, TRAS1–TRAS0, RASD, and
AMX3–AMX0 are written to in the initialization after a power-on reset and should not then be
modified again. When RFSH and RMODE are written to, write the same values to the other bits.
When using synchronous DRAM, do not access areas 2 and 3 until this register is initialized.
Bits 15 and 14—RAS Precharge Time (TPC1, TPC0): When synchronous DRAM interface is
selected as connected memory, they set the minimum number of cycles until output of the next
bank-active command after precharge. However, the number of cycles input immediately after the
issue of an all-bank-precharge command (PALL) in the case of an auto-refresh or a precharge
command (PRE) in the bank active mode is one fewer than the normal value. TPC1 should not be
set to 0 and TPC0 to 1 in the bank active mode.
Note: * Immediately after all-bank-precharge (PALL) in the case of an auto-refresh or precharge
Bit 15:
TPC1
0
1
Initial value:
Initial value:
(PRE) in the bank active mode.
Individual Memory Control Register (MCR)
Bit 14:
TPC0
0
1
0
1
R/W:
R/W:
Bit:
Bit:
RASD
TPC1
R/W
R/W
Normal Operation
1 cycle (Initial value)
2 cycles
3 cycles
4 cycles
15
0
7
0
AMX3
TPC0
R/W
R/W
14
0
6
0
RCD1
AMX2
R/W
R/W
13
0
5
0
Immediately after
Precharge Command *
0 cycle (Initial value)
1 cycle
2 cycles
3 cycles
RCD0
AMX1
R/W
R/W
12
0
4
0
Description
TRWL1 TRWL0
AMX0
R/W
R/W
11
0
3
0
Rev. 5.00, 09/03, page 245 of 760
RFSH
R/W
R/W
10
0
2
0
Immediately after
Self-Refresh
2 cycles (Initial value)
5 cycles
8 cycles
11 cycles
RMODE
TRAS1
R/W
R/W
9
0
1
0
TRAS0
R/W
R
8
0
0
0