MC9S08GB60ACFUE Freescale, MC9S08GB60ACFUE Datasheet - Page 237

MC9S08GB60ACFUE

Manufacturer Part Number
MC9S08GB60ACFUE
Description
Manufacturer
Freescale
Datasheet

Specifications of MC9S08GB60ACFUE

Cpu Family
HCS08
Device Core Size
8b
Frequency (max)
40MHz
Interface Type
I2C/SCI/SPI
Total Internal Ram Size
4KB
# I/os (max)
56
Number Of Timers - General Purpose
8
Operating Supply Voltage (typ)
2.5/3.3V
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
1.8/2.08V
On-chip Adc
8-chx10-bit
Instruction Set Architecture
CISC
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
64
Package Type
LQFP
Program Memory Type
Flash
Program Memory Size
60KB
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S08GB60ACFUE
Manufacturer:
EM
Quantity:
12 000
Part Number:
MC9S08GB60ACFUE
Manufacturer:
FREESCAL
Quantity:
1 045
Part Number:
MC9S08GB60ACFUE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S08GB60ACFUE
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC9S08GB60ACFUE
0
Part Number:
MC9S08GB60ACFUER
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
14.6.3
For left-justified mode, result data bits 9–2 map onto bits 7–0 of ATD1RH, result data bits 1 and 0 map
onto ATD1RL bits 7 and 6, where bit 7 of ATD1RH is the most significant bit (MSB).
Freescale Semiconductor
ATDCO
ATDCH
ATDIE
Field
CCF
4:0
7
6
5
ATD Result Data (ATD1RH, ATD1RL)
Conversion Complete Flag — The CCF is a read-only bit which is set each time a conversion is complete. The
CCF bit is cleared whenever the ATD1SC register is written. It is also cleared whenever the result registers,
ATD1RH or ATD1RL, are read.
0 Current conversion is not complete.
1 Current conversion is complete.
ATD Interrupt Enabled — When this bit is set, an interrupt is generated upon completion of an ATD conversion.
At this time, the result registers contain the result data generated by the conversion. The interrupt will remain
pending as long as the conversion complete flag CCF is set. If the ATDIE bit is cleared, then the CCF bit must
be polled to determine when the conversion is complete. Note that system reset clears pending interrupts.
0 ATD interrupt disabled.
1 ATD interrupt enabled.
ATD Continuous Conversion — When this bit is set, the ATD will convert samples continuously and update the
result registers at the end of each conversion. When this bit is cleared, only one conversion is completed between
writes to the ATD1SC register.
0 Single conversion mode.
1 Continuous conversion mode.
Analog Input Channel Select — This field of bits selects the analog input channel whose signal is sampled and
converted to digital codes.
Table 14-7. Analog Input Channel Select Coding
ATDCH
08–1D
1E
1F
00
01
02
03
04
05
06
07
Table 14-6. ATD1SC Field Descriptions
Table 14-7
MC9S08GB60A Data Sheet, Rev. 2
lists the coding used to select the various analog input channels.
Reserved (default to V
Analog Input Channel
Description
V
V
AD0
AD1
AD2
AD3
AD4
AD5
AD6
AD7
REFH
REFL
REFL
)
Analog-to-Digital Converter (S08ATDV3)
237