DV007003 Microchip Technology, DV007003 Datasheet - Page 94

no-image

DV007003

Manufacturer Part Number
DV007003
Description
PROGRAMMER UNIVERSAL PROMATE II
Manufacturer
Microchip Technology
Series
PRO MATE® IIr
Type
Universalr
Datasheets

Specifications of DV007003

Contents
Programmer, Power Supply, Assembler/Simulator, Cable, Software and Documentation
Positions/sockets
1
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
For Use With/related Products
PIC16C5x, PIC16Cxx and PIC17Cxx 8-Bit Micro
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Request inventory verification / Request inventory verification
PRO MATE II User’s Guide
DS30082J-page 88
PROCMD /1 /P16C54A /N4500 /X5500 /FPROGRAM.HEX
PRO MATE II on COM1 set to a PIC16C54A, V
set to 5.5V. V
the PRO MATE II.
PROCMD /1 /P16C54A /N4500 /X5500 /FPROGRAM.HEX /M
PRO MATE II on COM1 set to a PIC16C54A, V
set to 5.5V. V
the PRO MATE II. Device programmed with specified voltages. Only the
addresses specified in PROGRAM.HEX are programmed.
PROCMD /2 /P16C61 /FVOLTS.HEX
PRO MATE II on COM2 set to a PIC16C61, hex file VOLTS.HEX sent to the
PRO MATE II, voltages set to devices default values.
PROCMD /2 /P16C61 /FVOLTS.HEX /SSQTP.NUM /M
PRO MATE II on COM2 set to a PIC16C61, hex file VOLTS.HEX sent to the
PRO MATE II, voltages are set to the device’s default values, and one entry
from the SQTP file SQTP.NUM is sent. All of the device’s program memory is
programmed, with blank values in the locations not specified by VOLTS.HEX
and SQTP.NUM. Any other device areas specified by VOLTS.HEX are
programmed. If programming is successful, the SQTP entry is marked as
used.
PROCMD /2 /P16CR83 /FDATAMEM.HEX /M
PRO MATE II on COM2 is set to a PIC16CR83, the file DATAMEM.HEX is sent
to PRO MATE II, voltages are set to the device’s default values and the device
is programmed. Only the addresses specified in DATAMEM.HEX that are for
data memory and configuration bits are programmed.
PROCMD /3 /P17C42A /FAPPCODE.HEX /M
PRO MATE II on COM3 is set to a PIC17C42A, the file APPCODE.HEX is sent
to PRO MATE II, voltages are set to the device’s default values, and a device
is programmed. Only the addresses specified in APPCODE.HEX are
programmed.
PROCMD /3 /P17C42A /M
PRO MATE II on COM3 is set to a PIC17C42A, and a device is programmed
with the current contents of the device programmer at the currently selected
voltage levels.
PROCMD /3 /P17C42A /SSERIAL.NUM /M
PRO MATE II on COM3 is set to PIC17C42A, and one entry from the SQTP
file SERIAL.NUM is sent. A device is programmed with the current contents of
the device programmer and the serial number at the currently selected
voltages. If programming is successful, the entry is marked as used.
For information on error messages you may receive, see Section 8.4.
PP
PP
set to the device’s default value. File PROGRAM.HEX sent to
set to the device’s default value. File PROGRAM.HEX sent to
DD
DD
 2001 Microchip Technology Inc.
Min set to 4.5V, V
Min set to 4.5V, V
DD
DD
Max
Max

Related parts for DV007003