(3) Some commands are sent to the FP5 and the update progress status is displayed in the action log window. The
Remark
Remark
message “Firmware Update succeeds”, which indicates normal completion of firmware update, and “Restarting
FP5..”, which is equivalent to [RESET] command processing, is automatically performed. The new version can
then be checked as “Firmware Version Vx.xx”. The update takes about 10 seconds.
Depending on the changes made, the following dialog box will be displayed. In this case, the information
stored in the FP5 (PR5 file, ESF file, program file) will have been deleted, so please download those files
again. (Refer to 4.2 Starting the Programming GUI.)
The action log window is a part of the main window of the programming GUI, which shows the operation
progress status.
Figure 3-9. Action Log Window When Firmware Update Is Finished