PG-FP5-EA Renesas Electronics America, PG-FP5-EA Datasheet - Page 131

no-image

PG-FP5-EA

Manufacturer Part Number
PG-FP5-EA
Description
PROGRAMMER FLASH MEMORY UNIV
Manufacturer
Renesas Electronics America
Datasheets

Specifications of PG-FP5-EA

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
<R>
PG-FP5
[Option Setting >]
6.3.4
currently connected to the FP5. The settings downloaded to the valid programming area are displayed. The settings
cannot be changed using this menu.
[Voltage Setting >]
R20UT0008EJ0400 Rev. 4.00
Jul 15, 2010
The [Voltage Setting] menu is used to check the voltage level setting used when programming the target device
Main Menu
Main Menu
[Voltage Setting] menu
[OPBTx
x=0 to 8
[Vdd
[Vdd2
[Vdd Source
[Vdd Monitoring
[FLMD0 Level
[CLK Level
[RESET Level
[Serial Level
[Vpp
Submenu
Submenu
Table 6-3. [Option Setting] Menu (3/3)
] Displays the setting of the [Option bytes setting] box in the [Option bytes setting]
] Displays the setting of the [Vdd monitoring] check box in the [Supply voltage] area
] The Reset Level displays the voltage level of the RESET
] Indicates the voltage level of the serial communication signals. The high level of the
] Displays the value of V
] Displays the value of V
] Indicates the source of V
] The FLMD0 Level displays the voltage level of the FLMD0 signal.
] Indicates the voltage level of the clock signal as either of the following.
] Indicates the value of V
Table 6-4. [Voltage Setting] Menu
area on the [Advanced] tab in the Device Setup dialog box. If the [NEXT] button is
clicked, the display changes from OPBT0 to OPBTx.
Display example:
volts.
V
V
on the [Advanced] tab in the Device Setup dialog box.
on: Selected, off: Not selected
Also, when the [Enable target RESET] check box in the [Command options] area of
the device setup dialog [Advanced] is enabled, "VDD Reset TrigIn" is displayed.
serial communication signal is indicated as either of the following.
DD
DD
If FFFFFFE9 is specified for OPBT0 in the [Option bytes setting] area
OPBT0
FFFFFFE9
VDD
VDD2
VDD
VDD
VDD2
from PG: V
from device: V
DD
is supplied from the FP5.
DD
is supplied from the user system.
DD
DD2
PP
DD
supplied to the target device connected to the FP5 in volts.
supplied to the target device connected to the FP5 in volts.
supplied to the target device connected to the FP5 in
CHAPTER 6 USAGE IN STANDALONE MODE
supplied from the target device as either of the following.
Description
Description
¯¯¯¯¯¯ signal.
Page 131 of 240