PG-FP5
R20UT0008EJ0400 Rev. 4.00
Jul 15, 2010
050
051
060
061
062
063
070
071
072
073
080
081
090
091
092
093
094
204
210
301
No.
Bln Timeout
Blank chk failed
Wrb Timeout
Writeback failed
Wrb retry exceed
Wrb Timeset err
Write timeout
Write failed
Write retry err
Wrt. Timeset err
Vrf Timeout
Verify failed
IVrf Timeout
IVerify failed
VGT Comm err
SUM Comm err
SCF Comm err
Not connected
Already conn.
Security ID err
Message
Writeback time setting error
Write timed out
Write operation failed
Write retry error
Write time setting error
Verify failed
Internal verify timed out
Internal verify error
Device communication error
Device communication error
The target device was not connected
to FP5 when a ‘disconnect’ command
was issued.
A connect command was issued when
the target device was already
connected to FP5.
Blank check timed out
Blank check failed
Writeback timed out
Writeback failed
Writeback retry timed out
Verify timed out
Device communication error
Security ID does not match.
Error Condition
A communication problem occurred between the FP5 and
target device. Try the operation again.
The device connected is not empty. Use the ‘erase’
command before programming.
There was a communication problem between the FP5 and
target device. Try the operation again.
A device defect is most probably causing this error.
A device defect is most probably causing this error.
The parameter file may contain invalid data.
Contact Renesas Electronics.
There was a communication problem between the FP5 and
target device. Try the operation again.
Either the device was not blank before writing or a device
defect is causing this error.
Either the device was not blank before writing or a device
defect is causing this error.
The parameter file may contain invalid data. Contact
Renesas Electronics.
There was a communication problem between the FP5 and
target device. Try the operation again.
The data in the target device’s flash memory is not the
same as in the FP5.
There was a communication problem between the FP5 and
target device. Try the operation again.
An error was occurred while the write data level was being
checked.
The FP5 is not communicating properly with the target
device. Check that the FP5 is correctly connected to the
target device.
The FP5 is not communicating properly with the target
device. Check that the FP5 is correctly connected to the
target device.
The FP5 is not communicating properly with the target
device. Check that the FP5 is correctly connected to the
target device.
Please specify the Security ID as stored in the device.
Possible Workaround
APPENDIX A MESSAGES
Page 213 of 240
(2/3)