Z8F011ASH020EG2156 ZiLOG, Z8F011ASH020EG2156 Datasheet - Page 48

no-image

Z8F011ASH020EG2156

Manufacturer Part Number
Z8F011ASH020EG2156
Description
8-bit Microcontrollers - MCU 1K FLASH 256B RAM 16B NVDS
Manufacturer
ZiLOG
Datasheet

Specifications of Z8F011ASH020EG2156

Rohs
yes
Core
eZ8
Data Bus Width
8 bit
Maximum Clock Frequency
20 MHz
Program Memory Size
1 KB
Data Ram Size
256 B
On-chip Adc
No
Package / Case
SOIC-20
Mounting Style
SMD/SMT
Interface Type
UART
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
17
Number Of Timers
2
Program Memory Type
Flash
Supply Voltage - Max
3.6 V
Supply Voltage - Min
2.7 V
Low-Power Modes
PS025113-1212
STOP Mode
The Z8 Encore! F0830 Series products contain power saving features. The highest level of
power reduction is provided by the STOP Mode. The next level of power reduction is pro-
vided by the HALT Mode.
Further power savings can be implemented by disabling the individual peripheral blocks
while in NORMAL Mode.
The user must not enable the pull-up register bits for unused GPIO pins, since these ports
are default output to VSS. Unused GPIOs include those missing on 20-pin packages, as
well as those missing on the ADC-enabled 28-pin packages.
Executing the eZ8 CPU’s STOP instruction places the device into STOP Mode. In STOP
Mode, the operating characteristics are:
To minimize the current in STOP Mode, all GPIO pins that are configured as digital inputs
must be driven to V
(V
STOP Mode using Stop Mode Recovery. For more information about Stop Mode Recov-
ery, see the
DD
Primary crystal oscillator and Internal Precision Oscillator are stopped; XIN and
XOUT (if previously enabled) are disabled and PA0/PA1 revert to the states pro-
grammed by the GPIO registers
System clock is stopped
eZ8 CPU is stopped
Program counter (PC) stops incrementing
Watchdog Timer’s internal RC oscillator continues to operate if enabled by the Oscil-
lator Control Register
If enabled, the Watchdog Timer logic continues to operate
If enabled for operation in STOP Mode by the associated Flash option bit, the Voltage
Brown-Out protection circuit continues to operate
All other on-chip peripherals are idle
or GND) when the pull-up register bit is disabled. The device can be brought out of
Reset and Stop Mode Recovery
DD
when the pull-up register bit is enabled or to one of power rail
chapter on page 21.
Z8 Encore!
Product Specification
Low-Power Modes
®
F0830 Series
30