MMC2114 MOTOROLA [Motorola, Inc], MMC2114 Datasheet - Page 463

no-image

MMC2114

Manufacturer Part Number
MMC2114
Description
M CORE Microcontrollers
Manufacturer
MOTOROLA [Motorola, Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MMC2114CFCAF33
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MMC2114CFCAG33
Manufacturer:
Freescale Semiconductor
Quantity:
135
Part Number:
MMC2114CFCAG33
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MMC2114CFCAG33
Manufacturer:
FREESCALE
Quantity:
8 000
Part Number:
MMC2114CFCAG33
Manufacturer:
XILINX
0
Company:
Part Number:
MMC2114CFCAG33
Quantity:
62
Part Number:
MMC2114CFCPU33
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MMC2114CFCPV33
Manufacturer:
MOTOLOLA
Quantity:
853
19.8.7 Conversion Command Word Table (CCW)
MMC2114 • MMC2113 • MMC2112 — Rev. 1.0
MOTOROLA
CWPQ2[5:0] — Queue 2 Command Word Pointer Field
The conversion command word (CCW) table is 64 half-word (128 byte)
long RAM with 10 bits of each entry implemented. The CCW table is
written by the user and is not modified by the QADC. Each CCW
requests the conversion of one analog channel to a digital result. The
CCW specifies the analog channel number, the input sample time, and
whether the queue is to pause after the current CCW.
Finally, when queue 1 operation is terminated after a CCW is read
that is pointed to by BQ2, CWP points to BQ2 while CWPQ1 points to
the last queue 1 CCW.
During stop mode, CWPQ1 is reset to 63, because the control
registers and the analog logic are reset. When debug mode is
entered, CWPQ1 is not changed; it points to the last executed CCW
in queue 1.
CWPQ2[5:0] points to the last queue 2 CCW executed. This is a
read-only field with a valid range of 0 to 63; writes have no effect.
CWPQ2 always points to the last executed CCW in queue 2,
regardless which queue is active.
In contrast to CWP, CPWQ2 is updated when a conversion result is
written. When the QADC finishes a conversion in queue 2, both the
result register is written and CWPQ2 is updated.
During stop mode, CWPQ2 is reset to 63 because the control
registers and the analog logic are reset. When debug mode is
entered, CWPQ2 is not changed; it points to the last executed CCW
in queue 2.
Freescale Semiconductor, Inc.
For More Information On This Product,
Queued Analog-to-Digital Converter (QADC)
Go to: www.freescale.com
Queued Analog-to-Digital Converter (QADC)
Register Descriptions
Advance Information
463