FDC37M81 SMSC [SMSC Corporation], FDC37M81 Datasheet - Page 53

no-image

FDC37M81

Manufacturer Part Number
FDC37M81
Description
PC98/99 Compliant Enhanced Super I/O Controller with Keyboard/Mouse Wake-Up
Manufacturer
SMSC [SMSC Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FDC37M812
Manufacturer:
SMSC
Quantity:
1
Part Number:
FDC37M812
Manufacturer:
NEC
Quantity:
6 000
Part Number:
FDC37M812
Manufacturer:
SMSC
Quantity:
1 000
Part Number:
FDC37M812
Manufacturer:
SMSC
Quantity:
1 000
Part Number:
FDC37M812
Manufacturer:
SMSC
Quantity:
20 000
Part Number:
FDC37M813
Manufacturer:
FORTUNE
Quantity:
176
Part Number:
FDC37M813
Manufacturer:
SMSC
Quantity:
1 000
Part Number:
FDC37M817
Manufacturer:
SMSC
Quantity:
20 000
Part Number:
FDC37M817-MS
Manufacturer:
Microchip Technology
Quantity:
10 000
DATA TRANSFER COMMANDS
All of the Read Data, Write Data and Verify type
commands use the same parameter bytes and
return the same results information, the only
difference being the coding of bits 0-4 in the first
byte.
An implied seek will be executed if the feature
was enabled by the Configure command. This
seek is completely transparent to the user. The
Drive Busy bit for the drive will go active in the
Main Status Register during the seek portion of
the command.
reflected in the results status normally returned
for a Read/Write Data command. Status
Register 0 (ST0) would contain the error code
and C would contain the cylinder on which the
seek failed.
Read Data
A set of nine (9) bytes is required to place the
FDC in the Read Data Mode. After the Read
Data command has been issued, the FDC loads
the head (if it is in the unloaded state), waits the
specified head settling time (defined in the
Specify command), and begins reading ID
Address Marks and ID fields. When the sector
The amount of data which can be handled with
a single command to the FDC depends upon
MT (multi-track) and N (number of bytes/sector).
If the seek portion fails, it is
00
01
02
03
07
N
..
Table 19 - Sector Sizes
SECTOR SIZE
53
1024 bytes
16 Kbytes
128 bytes
256 bytes
512 bytes
address read off the diskette matches with the
sector address specified in the command, the
FDC reads the sector's data field and transfers
the data to the FIFO.
After completion of the read operation from the
current
incremented by one and the data from the next
logical sector is read and output via the FIFO.
This continuous read function is called "Multi-
Sector Read Operation". Upon receipt of TC, or
an implied TC (FIFO overrun/underrun), the
FDC stops sending data but will continue to
read data from the current sector, check the
CRC bytes, and at the end of the sector,
terminate the Read Data Command.
N determines the number of bytes per sector
(see Table 19 below). If N is set to zero, the
sector size is set to 128.
determines
transferred. If DTL is less than 128, the FDC
transfers the specified number of bytes to the
host. For reads, it continues to read the entire
128-byte sector and checks for CRC errors. For
writes, it completes the 128-byte sector by filling
in zeros. If N is not set to 00 Hex, DTL should
be set to FF Hex and has no impact on the
number of bytes transferred.
The Multi-Track function (MT) allows the FDC to
read data from both sides of the diskette. For a
particular cylinder, data will be transferred
starting at Sector 1, Side 0 and completing the
last sector of the same track at Side 1.
...
sector,
the
number
the
sector
of
The DTL value
bytes
address
to
be
is

Related parts for FDC37M81