mc68hc908mr32 Freescale Semiconductor, Inc, mc68hc908mr32 Datasheet - Page 175

no-image

mc68hc908mr32

Manufacturer Part Number
mc68hc908mr32
Description
M68hc08 Microcontrollers
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc68hc908mr32CB
Manufacturer:
FREESCALE
Quantity:
1 831
Part Number:
mc68hc908mr32CB
Manufacturer:
MOT
Quantity:
59
Part Number:
mc68hc908mr32CFU
Manufacturer:
FREESCALE
Quantity:
3
Part Number:
mc68hc908mr32CFU
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
IDLE — Receiver Idle Bit
OR — Receiver Overrun Bit
Freescale Semiconductor
This clearable, read-only bit is set when 10 or 11 consecutive 1s appear on the receiver input. IDLE
generates an SCI error CPU interrupt request if the ILIE bit in SCC2 is also set. Clear the IDLE bit by
reading SCS1 with IDLE set and then reading the SCDR. After the receiver is enabled, it must receive
a valid character that sets the SCRF bit before an idle condition can set the IDLE bit. Also, after the
IDLE bit has been cleared, a valid character must again set the SCRF bit before an idle condition can
set the IDLE bit. Reset clears the
IDLE bit.
This clearable, read-only bit is set when software fails to read the SCDR before the receive shift
register receives the next character. The OR bit generates an SCI error CPU interrupt request if the
ORIE bit in SCC3 is also set. The data in the shift register is lost, but the data already in the SCDR is
not affected. Clear the OR bit by reading SCS1 with OR set and then reading the SCDR. Reset clears
the OR bit.
Software latency may allow an overrun to occur between reads of SCS1 and SCDR in the flag-clearing
sequence.
caused by a delayed flag-clearing sequence. The delayed read of SCDR does not clear the OR bit
because OR was not set when SCS1 was read. Byte 2 caused the overrun and is lost. The next
flag-clearing sequence reads byte 3 in the SCDR instead of byte 2.
1 = Receiver input idle
0 = Receiver input active or idle since the IDLE bit was cleared
1 = Receive shift register full and SCRF = 1
0 = No receiver overrun
Figure 13-12
BYTE 1
BYTE 1
MC68HC908MR32 • MC68HC908MR16 Data Sheet, Rev. 6.1
shows the normal flag-clearing sequence and an example of an overrun
READ SCS1
READ SCDR
SCRF = 1
Figure 13-12. Flag Clearing Sequence
OR = 0
BYTE 1
READ SCDR
READ SCS1
DELAYED FLAG CLEARING SEQUENCE
BYTE 2
BYTE 2
NORMAL FLAG CLEARING SEQUENCE
SCRF = 1
BYTE 1
OR = 0
READ SCDR
READ SCS1
SCRF = 1
BYTE 2
OR = 0
BYTE 3
BYTE 3
READ SCDR
READ SCDR
READ SCS1
READ SCS1
SCRF = 1
SCRF = 1
BYTE 3
BYTE 3
OR = 1
OR = 0
BYTE 4
BYTE 4
I/O Registers
175