ade7518 Analog Devices, Inc., ade7518 Datasheet - Page 37
ade7518
Manufacturer Part Number
ade7518
Description
Single-phase Energy Measurement Ic With 8052 Mcu, Rtc, And Lcd Driver
Manufacturer
Analog Devices, Inc.
Datasheet
1.ADE7518.pdf
(128 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
ade7518ASTZF16
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Company:
Part Number:
ade7518ASTZF16-RL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Company:
Part Number:
ade7518ASTZF8
Manufacturer:
Analog Devices Inc
Quantity:
135
Company:
Part Number:
ade7518ASTZF8
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Company:
Part Number:
ade7518ASTZF8-RL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Table 33. WAVMODE Register (0x0D)
Bit
7 to 5
4 to 2
1 to 0
Table 34. NLMODE Register (0x0E)
Bit
7
6
5 to 4
3 to 2
1 to 0
Mnemonic
DISVARCMP
IRMSNOLOAD
VANOLOAD[1:0]
VARNOLOAD[1:0]
APNOLOAD[1:0]
Mnemonic
WAV2SEL[2:0]
WAV1SEL[2:0]
DTRT[1:0]
Default
0
0
00
00
00
Default
000
000
00
Description
Setting this bit disables fundamental VAR gain compensation over line frequency.
Logic 1 enables I
VANOLOAD bits.
Apparent Power No Load Threshold.
VANOLOAD[1:0]
00
01
10
11
Reactive Power No Load Threshold.
VARNOLOAD[1:0]
00
01
10
11
Active Power No Load Threshold.
APNOLOAD[1:0]
00
01
10
11
Description
Waveform 2 Selection for Samples Mode.
WAV2SEL[2:0]
000
001
010
011
100
101
Others
Waveform 1 Selection for Samples Mode.
WAV1SEL[2:0]
000
001
010
011
100
101
Others
Waveform Samples Output Data Rate.
DTRT[1:0]
00
01
10
11
rms
Rev. 0 | Page 37 of 128
no load threshold detection. The level is defined by the setting of the
Source
Current
Voltage
Active power multiplier output
Reactive power multiplier output
VA multiplier output
I
Reserved
rms
LPF output
Result
No load detection disabled
No load detection enabled with threshold = 0.030% of full scale
No load detection enabled with threshold = 0.015% of full scale
No load detection enabled with threshold = 0.0075% of full scale
Result
No load detection disabled
No load detection enabled with threshold = 0.015% of full scale
No load detection enabled with threshold = 0.0075% of full scale
No load detection enabled with threshold = 0.0037% of full scale
Result
No load detection disabled
No load detection enabled with threshold = 0.015% of full scale
No load detection enabled with threshold = 0.0075% of full scale
No load detection enabled with threshold = 0.0037% of full scale
Source
Voltage
Active power multiplier output
Reactive power multiplier output
VA multiplier output
Update Rate (Clock = f
25.6 kSPS (clock/32)
12.8 kSPS (clock/64)
6.4 kSPS (clock/128)
3.2 kSPS (clock/256)
Current
I
Reserved
rms
LPF output (low 24-bit)
CORE
/5 = 819.2 kHz)
ADE7518