ATxmega64A1 Atmel Corporation, ATxmega64A1 Datasheet - Page 158

no-image

ATxmega64A1

Manufacturer Part Number
ATxmega64A1
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATxmega64A1

Flash (kbytes)
64 Kbytes
Pin Count
100
Max. Operating Frequency
32 MHz
Cpu
8-bit AVR
# Of Touch Channels
16
Hardware Qtouch Acquisition
No
Max I/o Pins
78
Ext Interrupts
78
Usb Speed
No
Usb Interface
No
Spi
12
Twi (i2c)
4
Uart
8
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
2000
Analog Comparators
4
Resistive Touch Screen
No
Dac Channels
4
Dac Resolution (bits)
12
Temp. Sensor
Yes
Crypto Engine
AES/DES
Sram (kbytes)
4
Eeprom (bytes)
2048
Self Program Memory
YES
External Bus Interface
1
Dram Memory
sdram
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.6 to 3.6
Operating Voltage (vcc)
1.6 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
8
Output Compare Channels
24
Input Capture Channels
24
Pwm Channels
24
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATxmega64A1-AU
Manufacturer:
Atmel
Quantity:
135
Part Number:
ATxmega64A1-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega64A1-AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega64A1-C7U
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega64A1-C7UR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega64A1-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATxmega64A1U-AU
Manufacturer:
ATMEL
Quantity:
953
14.7.2
14.7.3
8077H–AVR–12/09
Frequency Capture
Pulse-width Capture
Selecting the frequency capture event action, makes the enabled capture channel perform an
input capture and restart on positive edge events. This enables Timer/Counter to use capture to
measure the period or frequency of a signal directly. The capture result will be the time, T, from
the previous Timer/Counter restart and until the event occurred. This can be used to calculate
the frequency, f, of the signal:
Figure 14-10 on page 158
nal signal.
Figure 14-10. Frequency capture of an external signal
Since all capture channels uses the same Counter (CNT), only one capture channels must be
enabled at a time. If two capture channels are used with different source, the Counter will be
restarted on positive edge events from both input sources, and the result from the input capture
will have no meaning.
Selecting the pulse-width measure event action makes the enabled compare channel perform
the input capture action on falling edge events and the restart action on rising edge events. The
counter will then start at zero at every start of a pulse and the input capture will be performed at
the end of the pulse. The event source must be an I/O pin and the sense configuration for the pin
must be set up to generate an event on both edges.
ple where the pulse width is measured twice for an external signal.
f
=
external signal
events
CNT
1
-- -
T
MAX
BOT
shows an example where the Period is measured twice for an exter-
Period (T)
Figure 14-11 on page 159
XMEGA A
shows and exam-
"capture"
158

Related parts for ATxmega64A1