AT32UC3A1512AU Atmel Corporation, AT32UC3A1512AU Datasheet - Page 22

no-image

AT32UC3A1512AU

Manufacturer Part Number
AT32UC3A1512AU
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3A1512AU

Flash (kbytes)
512 Kbytes
Pin Count
100
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
69
Ext Interrupts
69
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
1
Uart
4
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
16
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
64
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0-3.6 or (1.65-1.95+3.0-3.6)
Operating Voltage (vcc)
3.0-3.6 or (1.65-1.95+3.0-3.6)
Fpu
No
Mpu / Mmu
Yes / No
Timers
10
Output Compare Channels
16
Input Capture Channels
6
Pwm Channels
13
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3A1512AU-AUR
Manufacturer:
Atmel
Quantity:
10 000
32058K AVR32-01/12
9.2.1
Pipeline Overview
A local bus interface is provided for connecting the CPU to device-specific high-speed systems,
such as floating-point units and fast GPIO ports. This local bus has to be enabled by writing the
LOCEN bit in the CPUCR system register. The local bus is able to transfer data between the
CPU and the local bus slave in a single clock cycle. The local bus has a dedicated memory
range allocated to it, and data transfers are performed using regular load and store instructions.
Details on which devices that are mapped into the local bus space is given in the device-specific
“Peripherals” chapter of this data sheet.
Figure 9-1 on page 22
Figure 9-1.
AVR32 UC is a pipelined processor with three pipeline stages. There are three pipeline stages,
Instruction Fetch (IF), Instruction Decode (ID) and Instruction Execute (EX). The EX stage is
split into three parallel subsections, one arithmetic/logic (ALU) section, one multiply (MUL) sec-
tion and one load/store (LS) section.
Instructions are issued and complete in order. Certain operations require several clock cycles to
complete, and in this case, the instruction resides in the ID and EX stages for the required num-
ber of clock cycles. Since there is only three pipeline stages, no internal data forwarding is
required, and no data dependencies can arise in the pipeline.
Figure 9-2 on page 23
Instruction memory controller
High Speed Bus master
Overview of the AVR32UC CPU
system
displays the contents of AVR32UC.
shows an overview of the AVR32 UC pipeline stages.
OCD
AVR32UC CPU pipeline
MPU
master
Speed
High
Bus
Data memory controller
Bus slave
Speed
High
CPU Local
Power/
control
Reset
master
Bus
AT32UC3A
22