IDT82V2041EPP IDT, Integrated Device Technology Inc, IDT82V2041EPP Datasheet - Page 46

no-image

IDT82V2041EPP

Manufacturer Part Number
IDT82V2041EPP
Description
IC LIU T1/J1/E1 1CH 44-TQFP
Manufacturer
IDT, Integrated Device Technology Inc
Type
Line Interface Units (LIUs)r
Datasheet

Specifications of IDT82V2041EPP

Protocol
E1
Voltage - Supply
3.13 V ~ 3.47 V
Mounting Type
Surface Mount
Package / Case
44-TQFP, 44-VQFP
Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Package Type
TQFP
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Drivers/receivers
-
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
Other names
82V2041EPP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82V2041EPP
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2041EPP8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2041EPPG
Manufacturer:
IDT
Quantity:
351
Part Number:
IDT82V2041EPPG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2041EPPG8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Table-39 MAINT6: Maintenance Function Control Register 6
Programming Information
IDT82V2041E
EXZ_DEF
ERR_SEL
CNT_TRF
ERR_INS
BPV_INS
CNT_MD
Symbol
-
(R/W, Address = 13H)
3-2
Bit
7
6
5
5
1
0
Default
00
0
0
0
0
0
0
Reserved.
BPV error insertion
A ‘0’ to ‘1’ transition on this bit will cause a single bipolar violation error to be inserted into the transmit data stream.
This bit must be cleared and set again for a subsequent error to be inserted.
PRBS logic error insertion
A ‘0’ to ‘1’ transition on this bit will cause a single PRBS logic error to be inserted into the transmit PRBS data stream.
This bit must be cleared and set again for a subsequent error to be inserted.
EXZ definition select
= 0: ANSI
= 1: FCC
These bits choose which type of error will be counted
= 00: The PRBS logic error is counted by a 16-bit error counter.
= 01: The EXZ error is counted by a 16-bit error counter.
= 10: The Received CV (BPV) error is counted by a 16-bit error counter.
= 11: Both CV (BPV) and EXZ errors are counted by a 16-bit error counter.
Counter operation mode select
= 0: Manual Report mode
= 1: Auto Report mode
= 0: Clear this bit for the next ‘0’ to ‘1’ transition on this bit.
= 1: Error counting result is transferred to CNT0 and CNT1 and the error counter is reset.