IDT82V2041EPP IDT, Integrated Device Technology Inc, IDT82V2041EPP Datasheet - Page 44

no-image

IDT82V2041EPP

Manufacturer Part Number
IDT82V2041EPP
Description
IC LIU T1/J1/E1 1CH 44-TQFP
Manufacturer
IDT, Integrated Device Technology Inc
Type
Line Interface Units (LIUs)r
Datasheet

Specifications of IDT82V2041EPP

Protocol
E1
Voltage - Supply
3.13 V ~ 3.47 V
Mounting Type
Surface Mount
Package / Case
44-TQFP, 44-VQFP
Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Package Type
TQFP
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Drivers/receivers
-
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
Other names
82V2041EPP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82V2041EPP
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2041EPP8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2041EPPG
Manufacturer:
IDT
Quantity:
351
Part Number:
IDT82V2041EPPG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2041EPPG8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
4.3.4
Table-33 MAINT0: Maintenance Function Control Register 0
Table-34 MAINT1: Maintenance Function Control Register 1
Programming Information
IDT82V2041E
PATT_CLK
PRBS_INV
PATT[1:0]
Symbol
Symbol
ATAO
ARLP
AISE
LAC
RLP
DLP
ALP
NETWORK DIAGNOSTICS CONTROL REGISTERS
-
-
(R/W, Address = 0DH)
(R/W, Address= 0EH)
6-5
7-4
Bit
Bit
4
3
2
0
7
3
2
1
0
1
Default
Default
0000
00
00
0
0
0
0
0
0
0
0
0
Reserved.
These bits select the internal pattern and insert it into transmit data stream.
= 00: Normal operation (PATT_CLK = 0) / insert all zeros (PATT_CLK = 1)
= 01: Insert All Ones
= 10: Insert PRBS (E1: 2
= 11: Insert programmable Inband loopback activate or deactivate code (default value 00001)
Selects reference clock for transmitting internal pattern
= 0: Uses TCLK as the reference clock
= 1: Uses MCLK as the reference clock
Inverts PRBS
= 0: The PRBS data is not inverted
= 1: The PRBS data is inverted before transmission and detection
LOS/AIS criterion is selected as below:
= 0: G.775 (E1) / T1.231 (T1/J1)
= 1: ETSI 300233& I.431 (E1) / I.431 (T1/J1)
AIS enable during LOS
= 0: AIS insertion on RDP/RDN/RCLK is disabled during LOS
= 1: AIS insertion on RDP/RDN/RCLK is enabled during LOS
Automatically Transmit All Ones (enabled only when PATT[1:0] = 00)
= 0: Disabled
= 1: Automatically Transmit All Ones pattern at TTIP/TRING during LOS
Reserved
Automatic remote loopback enable
= 0: Disables automatic remote loopback (normal transmit and receive operation)
= 1: Enables automatic remote loopback
Remote loopback enable
= 0: Disables remote loopback (normal transmit and receive operation)
= 1: Enables remote loopback
Analog loopback enable
= 0: Disables analog loopback (normal transmit and receive operation)
= 1: Enables analog loopback
Digital loopback enable
= 0: Disables digital loopback (normal transmit and receive operation)
= 1: Enables digital loopback
15
SINGLE CHANNEL T1/E1/J1 SHORT HAUL LINE INTERFACE UNIT
-1) or QRSS (T1/J1: 2
44
20
Description
Description
-1)
December 9, 2005

Related parts for IDT82V2041EPP