Specifications of MTCMR-H4-P1-GB/IE

Function
Transceiver, HSPA, Modem
Modulation Or Protocol
GPRS, GSM, EDGE
Frequency
850MHz, 900MHz, 1.8GHz, 1.9GHz
Applications
General Purpose
Interface
RS-232, USB
Data Rate - Maximum
7.2 Mbps
Features
UK Power Cord
Voltage - Supply
9 V ~ 32 V, USB
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1122
X Set Connect Result Code Format and Call Monitoring
Z Set All Current Parameters to User-Defined Profile
High Speed HSPA-H4 AT Commands Reference Guide (Document S000483A)
Description:
Syntax:
Parameter Description:
Description:
Syntax:
Parameter Description:
<value>
Exec. Command:
Exec. Response:
<value>
Exec. Command:
Exec. Response:
0
0
1
2
3
4
ATX determines whether or not the TA transmits particular result codes to the TE. It also
controls whether or not the TA verifies the presence of a dial tone when it begins dialing,
and whether or not engaged tone (busy signal) detection is enabled.
CONNECT result code only returned. Dial tone and busy detection are both disabled.
Default.
CONNECT <text> result code only returned. Dial tone and busy detection are both
disabled.
CONNECT <text> result code returned. Dial tone detection is enabled; busy detection is
disabled.
CONNECT <text> result code returned. Dial tone detection is disabled; busy detection is
enabled.
CONNECT <text> result code returned. Dial tone and busy detection are both enabled.
Default.
ATZ sets all current parameters to the default configuration. It does not change DCE
baud rate or PDP context profiles.
ATX[<value>]
OK
ERROR
ATZ[<value>]
OK
Reset to user profile
Chapter 3 – Supported GSM/WCDMA AT Commands