Specifications of MTCMR-H4-P1-GB/IE

Function
Transceiver, HSPA, Modem
Modulation Or Protocol
GPRS, GSM, EDGE
Frequency
850MHz, 900MHz, 1.8GHz, 1.9GHz
Applications
General Purpose
Interface
RS-232, USB
Data Rate - Maximum
7.2 Mbps
Features
UK Power Cord
Voltage - Supply
9 V ~ 32 V, USB
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1122
+CLCK Facility Lock
High Speed HSPA-H4 AT Commands Reference Guide (Document S000483A)
Description:
Syntax:
Values:
Parameter Storage:
Examples:
This command is used by the application to lock, unlock or ask for a Mobile Equipment (ME)
or network facility.
<fac>
<mode>
<password> Password Code
<class>
<status>
Command
Action Command: AT+CLCK= <fac>,<mode>
[,<passwd>[,<class>] ]
Read Command: AT+CLCK?
Test Command: AT+CLCK=?
Command
AT+CLCK=?
AT+CLCK=”SC”,1,1234
Note: Activate PIN locking, 1234 is PIN1/CHV1
AT+CLCK=”SC”,2
AT+CLCK?
PS
SC
AO
OI
OX
AI
IR
AB
AG
AC
FD
PN
PU
PP
PC
0
1
0
1
2
7
8
0
1
Query status
Facility
SIM lock facility with an 8-digit password.
PIN enabled (<mode> = 1) / disabled (<mode> = 0)
BAOC (Barr All Outgoing Calls)
BOIC (Barr Outgoing International Calls)
BOIC-exHC (Barr Outgoing. International Calls except to Home Country)
BAIC (Barr All Incoming Calls)
BIC-Roam (Barr Incoming When Roaming outside Home Country)
All Barring services
All out Going barring services
All in Coming barring services
SIM Fixed Dialing Numbers (FDN) memory feature (PIN2/CHV2 is required as
<password>)
Network lock with an 8 digit password (NCK)
Network subset lock with an 8 digit password (NSCK)
Service Provider lock with an 8 digit password (SPCK)
Corporate lock with an 8 digit password (CCK)
Requested Operation
Unlock the facility
Lock the facility
String type. 4 to 8 or 16 digits depending on <fac>
Call Class. The combination of different classes is not supported. It will only
Voice (telephony)
Data
Voice and data. Default value if omitted.
Short Messages
Facility Lock Status
Not Active
Active
The <mode> and <password> parameters are stored in EEPROM and SIM
(depending on <fac>) without using the AT&W command.
result in the activation/deactivation/status request of all classes (7).
Chapter 3 – Supported GSM/WCDMA AT Commands
Responses
+CLCK:
(“PS”,”SC”,”AO”,”OI”,”OX”,”AI”,”IR”,”AB”,
"AG",”AC”, ”FD”,"PN","PU","PP",”PC”)
OK
OK
+CLCK: 1
OK
+CLCK:(“PS”,0),(“SC”,1),(“FD”,0),(“PN“,0),
(“PU“,0),(“PP“,0),(“PC“,0)
OK
Responses
[+CLCK: <status> <class1>[….]]
OK
+CLCK: (<fac>,<status>),[….]
+CLCK: list of supported (<fac>s)
OK
104