CRT1-OD16SL-1 Omron, CRT1-OD16SL-1 Datasheet - Page 80

no-image

CRT1-OD16SL-1

Manufacturer Part Number
CRT1-OD16SL-1
Description
16 Out PNP Cage Clamp
Manufacturer
Omron
Datasheet

Specifications of CRT1-OD16SL-1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Installing Slave Units
Mounting Dimensions
Mounting Procedure
56
46 24
1,2,3...
46
24
CRT1B-@D02JS(-1)
CRT1B-@D04JS(-1)
1. Mount the Unit using two M4 screws in the mounting holes A or the mount-
2. As shown in the following figure, press in on the Unit until the internal
A
ing holes B. Tighten the screws to the following torque.
hooks of the Mounting Bracket make a clicking sound. After mounting the
Unit, be sure to check that the Bit Slave Unit with Compact Connectors is
correctly mounted to the Mounting Bracket.
• Tightening torque: 0.9 N·m
25.4
27.05
6.65
B
20
20.4
15
Section 3-1