CRT1-OD16SL-1 Omron, CRT1-OD16SL-1 Datasheet - Page 433

no-image

CRT1-OD16SL-1

Manufacturer Part Number
CRT1-OD16SL-1
Description
16 Out PNP Cage Clamp
Manufacturer
Omron
Datasheet

Specifications of CRT1-OD16SL-1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Alarm Status Area
9-2
Two-point Input Units
Four-point Input Units
Allocating I/O Data
Allocating I/O Data
Note
The Bit Slave Unit’s Alarm Status Area contains the following 16 bits. These
bits indicate serious errors in the Unit.
Bit Slave Units with Compact Connectors support only the EEPROM Data
Error Flag.
Bit Slave Units are allocated node address areas in units of two points (two
bits).
Bit Input Area
Bit Input Area
Bit
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
• Input Units and Output Units
• I/O Units
Units with two points are allocated two bits (the node address set for the
Unit).
Units with four points are allocated four bits (the node address set for the
Unit and the next node address area).
Units are allocated four bits (the input and output node address areas).
Reserved
EEPROM Data Error Flag
OFF: Normal
ON: Error occurred
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Power Short-circuit Detection Flag
OFF: Normal
ON: Short-circuit
Load Short-circuit Detection Flag
OFF: Normal
ON: Short-circuit
Reserved
Reserved
Reserved
Reserved
Content
---
Turns ON when there is an error in
the EEPROM data.
---
---
---
---
---
---
---
---
Turns ON when there is a short in the
power supply connection to the con-
nected devices, including wiring mis-
takes and connected device failure.
Turns ON when there is a short in the
load connection, including wiring mis-
takes and connected device failure.
---
---
---
---
3
2
Description
1
1
0
0
Section 9-2
409