MFRC53101T/0FE,112 NXP Semiconductors, MFRC53101T/0FE,112 Datasheet - Page 34

IC MIFARE HS READER 32-SOIC

MFRC53101T/0FE,112

Manufacturer Part Number
MFRC53101T/0FE,112
Description
IC MIFARE HS READER 32-SOIC
Manufacturer
NXP Semiconductors
Series
MIFARE®r
Datasheets

Specifications of MFRC53101T/0FE,112

Rf Type
Read Only
Frequency
13.56MHz
Features
ISO14443-A, ISO14443-B, ISO15693
Package / Case
32-SOIC (0.300", 7.50mm Width)
Product
RFID Readers
Operating Temperature Range
- 25 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-2224-5
935269691112
MFRC531
MFRC53101TD

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MFRC53101T/0FE,112
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
MFRC531_34
Product data sheet
PUBLIC
9.10.2.2 Amplifier
Automatic calibration can be set-up to execute at the end of each Transceive command if
bit ClkQCalib = logic 0. Setting bit ClkQCalib = logic 1 disables all automatic calibrations
except after the reset sequence. Automatic calibration can also be triggered by the
software when bit ClkQCalib has a logic 0 to logic 1 transition.
Remark: The duration of the automatic Q-clock calibration is 65 oscillator periods or
approximately 4.8 μs.
The ClockQControl register’s ClkQDelay[4:0] value is proportional to the phase-shift
between the Q-clock and the I-clock. The ClkQ180Deg status flag bit is set when the
phase-shift between the Q-clock and the I-clock is greater than 180°.
Remark:
The demodulated signal must be amplified by the variable amplifier to achieve the best
performance. The gain of the amplifiers can be adjusted using the RxControl1 register
Gain[1:0] bits; see
Table 27.
See
Register setting
00
01
10
11
Fig 12. Automatic Q-clock calibration
The StartUp configuration file enables automatic Q-clock calibration after a reset
If bit ClkQCalib = logic 1, automatic calibration is not performed. Leaving this bit set to
logic 1 can be used to permanently disable automatic calibration.
It is possible to write data to the ClkQDelay[4:0] bits using the microprocessor. The
aim could be to disable automatic calibration and set the delay using the software.
Configuring the delay value using the software requires bit ClkQCalib to have been
previously set to logic 1 and a time interval of at least 4.8 μs has elapsed. Each delay
value must be written with bit ClkQCalib set to logic 1. If bit ClkQCalib is logic 0, the
configured delay value is overwritten by the next automatic calibration interval.
Table 83 “RxControl1 register bit descriptions” on page 61
Gain factors for the internal amplifier
Table
Transceive command
from reset sequence
Rev. 3.4 — 26 January 2010
calibration impulse
calibration impulse
27.
from end of
056634
ClkQCalib bit
Gain factor [dB]
(simulation results)
20
24
31
35
a rising edge initiates
Q-clock calibration
for additional information.
001aak616
ISO/IEC 14443 reader IC
MFRC531
© NXP B.V. 2010. All rights reserved.
34 of 116