D12312SVF20V Renesas Electronics America, D12312SVF20V Datasheet - Page 804

IC H8S/2312S MCU ROMLESS 100QFP

D12312SVF20V

Manufacturer Part Number
D12312SVF20V
Description
IC H8S/2312S MCU ROMLESS 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of D12312SVF20V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
70
Program Memory Type
ROMless
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
For Use With
EDK2329 - DEV EVALUATION KIT H8S/2329
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12312SVF20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 17 ROM
Table 17.62 Programming/Erasing Command
Command
H'42
H'43
H'50
H'48
H'58
H'52
H'4A
H'4B
H'4C
H'4D
H'4F
(1) Programming
Programming is executed by a programming-selection command and an 128-byte programming
command.
Firstly, the host should send the programming-selection command and select the programming
method and programming MATs. There are two programming selection commands, and selection
is according to the area and method for programming.
• User boot MAT programming selection
• User MAT programming selection
After issuing the programming selection command, the host should send the 128-byte
programming command. The 128-byte programming command that follows the selection
command represents the data programmed according to the method specified by the selection
command. When more than 128-byte data is programmed, 128-byte commands should repeatedly
be executed. Sending an 128-byte programming command with H'FFFFFFFF as the address will
stop the programming. On completion of programming, the boot program will wait for selection
of programming or erasing.
Rev.7.00 Feb. 14, 2007 page 770 of 1108
REJ09B0089-0700
Command Name
User boot MAT programming selection Transfers the user boot MAT programming
User MAT programming selection
128-byte programming
Erasing selection
Block erasing
Memory read
User boot MAT sum check
User MAT sum check
User boot MAT blank check
User MAT blank check
Boot program status inquiry
Description
program
Transfers the user MAT programming
program
Programs 128 bytes of data
Transfers the erasing program
Erases a block of data
Reads the contents of memory
Checks the checksum of the user boot MAT
Checks the checksum of the user MAT
Checks whether the contents of the user boot
MAT are blank
Checks whether the contents of the user MAT
are blank
Inquires into the boot program's status

Related parts for D12312SVF20V