D12312SVF20V Renesas Electronics America, D12312SVF20V Datasheet - Page 133

IC H8S/2312S MCU ROMLESS 100QFP

D12312SVF20V

Manufacturer Part Number
D12312SVF20V
Description
IC H8S/2312S MCU ROMLESS 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of D12312SVF20V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
70
Program Memory Type
ROMless
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
For Use With
EDK2329 - DEV EVALUATION KIT H8S/2329
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12312SVF20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
4.1
4.1.1
As table 4.1 indicates, exception handling may be caused by a reset, trap instruction, or interrupt.
Exception handling is prioritized as shown in table 4.1. If two or more exceptions occur
simultaneously, they are accepted and processed in order of priority. Trap instruction exceptions
are accepted at all times in the program execution state.
Exception handling sources, the stack structure, and the operation of the CPU vary depending on
the interrupt control mode set by the INTM0 and INTM1 bits of SYSCR.
Table 4.1
Priority
High
Low
Notes: 1. Traces are enabled only in interrupt control mode 2. Trace exception handling is not
2. Interrupt detection is not performed on completion of ANDC, ORC, XORC, or LDC
3. Trap instruction exception handling requests are accepted at all times in the program
Overview
Exception Handling Types and Priority
Exception Type
Reset
Trace *
Interrupt
Trap instruction (TRAPA) *
executed after execution of an RTE instruction.
instruction execution, or on completion of reset exception handling.
execution state.
Exception Types and Priority
1
Section 4 Exception Handling
3
Start of Exception Handling
Starts immediately after a low-to-high transition at the RES
pin, or when the watchdog timer overflows.
Starts when execution of the current instruction or exception
handling ends, if the trace (T) bit is set to 1
Starts when execution of the current instruction or exception
handling ends, if an interrupt request has been issued *
Started by execution of a trap instruction (TRAPA)
Rev.7.00 Feb. 14, 2007 page 99 of 1108
Section 4 Exception Handling
REJ09B0089-0700
2

Related parts for D12312SVF20V